Product Recall Check API: CPSC, NHTSA, FDA & EU Safety Gate avatar

Product Recall Check API: CPSC, NHTSA, FDA & EU Safety Gate

Pricing

from $5.00 / 1,000 product checks

Go to Apify Store
Product Recall Check API: CPSC, NHTSA, FDA & EU Safety Gate

Product Recall Check API: CPSC, NHTSA, FDA & EU Safety Gate

Recalled yes/no, with each recall's date, hazard, remedy and official link, for a product name, brand, model, UPC/EAN or VIN. Checks US CPSC, NHTSA vehicle recalls, FDA enforcement reports (food, drugs, devices) and EU Safety Gate in one call. Lists every source checked.

Pricing

from $5.00 / 1,000 product checks

Rating

0.0

(0)

Developer

Bosco Labs

Bosco Labs

Maintained by Community

Actor stats

0

Bookmarked

2

Total users

1

Monthly active users

7 days ago

Last modified

Features

Limited permissions

Share

Answers "is this product recalled anywhere, and for what hazard?" for a product name, brand, model, UPC/EAN barcode or VIN: one row per query with recalled yes/no, each recall's date, hazard, remedy and official link, from US CPSC, NHTSA, FDA enforcement reports and the EU Safety Gate. Built for AI agents in e-commerce, resale, procurement and product compliance, and for people who want one sourced answer instead of four searches.

Pricing (pay per event): $0.005 per product checked, recall found or not. A query where a source could not be checked is returned with a warning and costs nothing.

What you get

One row per query. Real output for {"queries": ["Peloton Bike+"]} (run on 2026-11-06, shortened to one of three matches):

{
"schema_version": "1",
"query": "Peloton Bike+",
"query_type": "text",
"vehicle": null,
"recalled": true,
"match_count": 3,
"summary": "Recall found for 'Peloton Bike+': 3 match(es) in US CPSC recalls. Newest: US CPSC recalls 2025-11-06 'Peloton Recalls Original Series Bike+ Exercise Bikes Due to Fall and Injury Hazards', hazard: The bike's seat post assembly can break during use, posing fall and injury hazards to the user. Matching is by words: confirm the exact model at source_url.",
"matches": [
{
"source": "cpsc",
"source_name": "US CPSC recalls",
"recall_id": "26067",
"date": "2025-11-06",
"title": "Peloton Recalls Original Series Bike+ Exercise Bikes Due to Fall and Injury Hazards",
"product": "Peloton Original Series Bike+ Model PL02",
"firm": "Peloton Interactive Inc., of New York",
"hazard": "The bike's seat post assembly can break during use, posing fall and injury hazards to the user.",
"remedy": "Consumers should immediately stop using the recalled exercise bikes and contact Peloton for a free repair. Peloton is offering consumers a free seat post that can be self-installed.",
"classification": null,
"status": null,
"jurisdiction": "US",
"source_url": "https://www.cpsc.gov/Recalls/2026/Peloton-Recalls-Original-Series-Bike-Exercise-Bikes-Due-to-Fall-and-Injury-Hazards"
}
],
"sources_checked": [
{"source": "cpsc", "source_name": "US CPSC recalls", "ok": true, "matches": 3, "coverage": "all CPSC recalls"},
{"source": "fda_food", "source_name": "US FDA enforcement reports (food)", "ok": true, "matches": 0, "coverage": "the 100 newest matching enforcement reports"},
{"source": "fda_drug", "source_name": "US FDA enforcement reports (drugs)", "ok": true, "matches": 0, "coverage": "the 100 newest matching enforcement reports"},
{"source": "fda_device", "source_name": "US FDA enforcement reports (medical devices)", "ok": true, "matches": 0, "coverage": "the 100 newest matching enforcement reports"},
{"source": "eu_safety_gate", "source_name": "EU Safety Gate alerts", "ok": true, "matches": 0, "coverage": "weekly reports 2025-11-07 to 2026-11-06 (52 weeks)"}
],
"warnings": [],
"input_error": null,
"source_url": "https://www.cpsc.gov/Recalls/2026/Peloton-Recalls-Original-Series-Bike-Exercise-Bikes-Due-to-Fall-and-Injury-Hazards",
"checked_at": "2026-11-06T06:38:16+00:00"
}

A vehicle ("2012 Honda Accord", or a VIN such as "1HGCP2F31CA000000", which is decoded with NHTSA vPIC first) returns NHTSA campaigns, here 8, newest first:

{
"source": "nhtsa",
"recall_id": "19V502000",
"date": "2019-06-27",
"title": "AIR BAGS:FRONTAL:PASSENGER SIDE:INFLATOR MODULE",
"product": "2012 HONDA ACCORD",
"firm": "Honda (American Honda Motor Co.)",
"hazard": "An inflator explosion may result in sharp metal fragments striking the driver or other occupants resulting in serious injury or death.",
"remedy": "Honda will notify owners, and dealers will replace the passenger frontal air bag inflator, free of charge. The recall began August 12, 2019. ...",
"jurisdiction": "US",
"source_url": "https://api.nhtsa.gov/recalls/campaignNumber?campaignNumber=19V502000"
}
  • recalled: true (a recall or alert matched), false (every source that applies answered and none matched) or null (nothing matched, but a source was down: see warnings).
  • matches: newest first, at most maxMatches; match_count is the total.
  • sources_checked: every source behind the answer and what it covered (the EU weeks searched, for example). Put this in your audit trail.
  • warnings: a source that could not be checked, in plain words. One source being down never fails the run. input_error: why a query could not be checked at all (a VIN with a wrong check digit, say); null otherwise.
  • Each row also carries attribution (the source notices: CPSC credit, the openFDA disclaimer and the EU Safety Gate acknowledgement) and provided_by.

Input

{ "queries": ["Peloton Bike+", "3418178586009", "1HGCP2F31CA000000"], "maxMatches": 10 }
FieldMeaning
queries1-50 entries: a product name, brand or model; a UPC/EAN (8-14 digits); a 17-character VIN; or year make model (2012 Honda Accord). Required
maxMatchesRecalls listed per query, newest first. 1-50, default 10
sourcesAny of cpsc, nhtsa, fda_food, fda_drug, fda_device, eu_safety_gate. Default all
euWeeksLatest weekly EU Safety Gate reports to search. 1-260, default 52 (one year)

How queries are read and matched: digits only (8-14) = a barcode, matched against CPSC UPCs, FDA product codes and Safety Gate barcodes (whole numbers only). 17 letters and digits = a VIN, decoded to make, model and year with NHTSA vPIC, then checked against NHTSA and Safety Gate. A VIN that vPIC flags (for example a wrong check digit, usually a typo) is not guessed at: the row gets input_error with vPIC's own message, and if every query is such a VIN the run fails fast with that message and a valid example. A leading or trailing year = a vehicle; it is checked against NHTSA and, in case it is a dated product name, the product sources too. Anything else is text: every word of the query must start a word in the recall's product name, model, brand/firm or description ("bike" finds "Bikes", not "motorbike").

Use from an AI agent (MCP)

Agents can call this Actor as a tool through the Apify MCP server. Add this server URL to your MCP client (Claude, Cursor, VS Code, ...):

https://mcp.apify.com?tools=bosco_labs/product-recalls

It loads this Actor as a tool, plus the tools that read its results (get-actor-run, get-dataset-items). The hosted server signs you in with OAuth, or accepts your Apify token as Authorization: Bearer <APIFY_TOKEN>.

Example prompt: "Before we list this used Peloton Bike+ and this 2012 Honda Accord for sale, check whether either has been recalled, for what hazard, and cite the source." The agent passes:

{ "queries": ["Peloton Bike+", "2012 Honda Accord"] }

Output for agents: one row per query (typically 2-9 KB), stable snake_case fields, ISO dates, null for unknown. summary is one sentence the agent can repeat; recalled is the yes/no/unknown; source_url is the official record. A run takes about 12 seconds (measured on 2026-11-06 for the two queries above; most of it is reading the 52 weekly EU reports, which are read once per run however many queries you send).

Cost: $0.005 per product checked, billed to the Apify account the MCP server is signed in with. Nothing is charged for a query where a source failed.

FAQ

Why is "no recall found" charged? Because it is the answer you asked for: every source that applies was searched and none had a match, and sources_checked documents what was covered. That is the result a reseller or compliance check needs on file. What is never charged: a query where any applicable source could not be checked (the row is returned with warnings and recalled: null if nothing matched), a VIN that does not decode cleanly (input_error), bad input, or a run where no source answered.

How reliable is a match? Matching is by words, so it is fuzzy both ways. A common word can match unrelated products ("charger"), and a product listed under another name or spelling can be missed. Brand + model ("Peloton Bike+", "Philips DreamStation") works best; a model number or barcode is most precise. Always confirm the exact model, batch or date range at source_url before acting: a recall often covers only some serial numbers or production dates.

Does a VIN match mean that car is affected? Not necessarily. NHTSA's open recalls API works by year, make and model, so the answer lists recalls for that model line. Whether one specific vehicle is included, or was already repaired, only the manufacturer or NHTSA's VIN lookup at nhtsa.gov/recalls can say (that page uses a CAPTCHA, so this Actor does not use it).

What is covered?

SourceWhatHistory
cpsc US Consumer Product Safety CommissionConsumer product recalls (toys, furniture, appliances, sporting goods, ...)All published recalls
nhtsa US NHTSAVehicle recalls by year, make and modelAll campaigns for that vehicle
fda_food, fda_drug, fda_device openFDAFDA enforcement reports: food (incl. infant formula, supplements), drugs, medical devicesThe 100 newest matching reports per category
eu_safety_gate European CommissionEU/EEA alerts on dangerous non-food products and vehiclesThe latest euWeeks weekly reports (default 52, up to 260)

What is not covered? Car seats, tyres and other vehicle equipment (NHTSA equipment recalls), EU food alerts (RASFF), UK, Canadian, Australian and other national recall lists, USDA meat and poultry recalls, and recall photos. FDA enforcement reports can lag the press release by a few weeks.

How fresh is it? Every run queries the sources live. CPSC, NHTSA and openFDA update as the agencies publish; EU Safety Gate publishes a weekly report every Friday.

Attribution. Recall data: U.S. Consumer Product Safety Commission (CPSC); no endorsement by CPSC implied. Vehicle recall data: U.S. NHTSA (public information); no endorsement implied. FDA enforcement reports via openFDA (CC0); do not rely on openFDA to make decisions regarding medical care. Alerts from the Rapid Alert System for dangerous non-food products, published free of charge on the Safety Gate website (https://ec.europa.eu/safety-gate-alerts) © European Union, 2005-2026; shortened and reformatted, not otherwise changed. Reuse terms of each source, quoted: see LEGAL.md.