FDA Recalls & 510(k) Clearances Scraper (openFDA API)
Pricing
from $2.00 / 1,000 fda records
FDA Recalls & 510(k) Clearances Scraper (openFDA API)
FDA medical device, drug and food recalls (enforcement reports) and 510(k) device clearances from the public openFDA API. Filter by class, status, keyword, firm, state and date. Newest first. Regulatory monitoring and medtech competitive intelligence. No API key needed.
FDA Recalls (Device, Drug, Food) & 510(k) Clearances Scraper — openFDA API
Extract official U.S. Food and Drug Administration (FDA) Enforcement Recall Reports (device_enforcement, drug_enforcement, food_enforcement) and 510(k) Premarket Notification Clearances (device_510k) from the official openFDA JSON APIs (api.fda.gov).
Supports deep cursor pagination via the Link: <...>; rel="next" (search_after) response header to bypass openFDA's 25,000 skip cap, normalizes all FDA YYYYMMDD dates to ISO YYYY-MM-DD, and works out of the box without an API key (or accepts an optional openFdaApiKey for 120,000 requests/day).
Who it's for
- Regulatory affairs, quality assurance (QA/RA) & compliance teams monitoring Class I, Class II, and Class III recalls across medical devices, pharmaceuticals, and food products
- MedTech commercial, competitive intelligence & BD teams tracking newly cleared 510(k) devices (
kNumber,deviceName,applicant,contact,productCode,regulationNumber) - Supply chain, hospital procurement, legal & risk management analysts auditing vendor recall histories and UDI/lot code notices (
codeInfo)
Input
By default, the Actor pulls up to 200 Class I and Class II medical device enforcement recalls reported in the past 90 days.
{"dataset": "device_enforcement","classifications": ["Class I", "Class II"],"statuses": ["Ongoing"],"keywords": ["catheter", "infusion pump"],"firmName": "","states": ["CA", "MN"],"dateFrom": "2026-07-25","dateTo": "2026-10-23","maxItems": 200}
| Field | Type | Default | Description |
|---|---|---|---|
dataset | string | "device_enforcement" | device_enforcement, drug_enforcement, food_enforcement, or device_510k. |
classifications | array | ["Class I", "Class II"] | Hazard classifications (Class I, Class II, Class III) — applies to enforcement datasets only. |
statuses | array | [] (all) | Recall statuses (Ongoing, Completed, Terminated, Pending) — enforcement only. |
keywords | array of strings | [] (all) | Matched in product_description or reason_for_recall (enforcement) or device_name (device_510k). |
firmName | string | "" (all) | Matched against recalling_firm (enforcement) or applicant (device_510k). |
states | array of strings | [] (all) | 2-letter US state codes (e.g. ["CA", "MN"]). |
dateFrom | string (YYYY-MM-DD) | today - 90 days | Start of report_date (enforcement; minimum 2012-06-20) or decision_date (device_510k). |
dateTo | string (YYYY-MM-DD) | today | End of report_date or decision_date. |
openFdaApiKey | string (secret) | "" | Optional free openFDA API key (increases quota from 1,000/day to 120,000/day). |
maxItems | integer | 200 | Maximum number of rows to output. |
Output
Every output row includes a dataset field identifying the source dataset.
Enforcement datasets (device_enforcement, drug_enforcement, food_enforcement)
| Field | Type | Description |
|---|---|---|
dataset | string | device_enforcement, drug_enforcement, or food_enforcement |
recallNumber | string | null | FDA recall number (e.g. Z-3183-2026) |
eventId | string | null | FDA recall event ID |
productType | string | null | Devices, Drugs, or Food |
classification | string | null | Class I, Class II, or Class III |
status | string | null | Ongoing, Completed, Terminated, or Pending |
recallingFirm | string | null | Recalling firm name |
city / state / country | string | null | Recalling firm location |
reportDate | string | null | Enforcement report publication date (YYYY-MM-DD) |
recallInitiationDate | string | null | Recall initiation date (YYYY-MM-DD) |
centerClassificationDate | string | null | FDA classification date (YYYY-MM-DD) |
terminationDate | string | null | Recall termination date (YYYY-MM-DD) |
voluntaryMandated | string | null | Voluntary vs. FDA-mandated status |
initialFirmNotification | string | null | Initial firm notification method |
distributionPattern | string | null | Geographic distribution pattern |
productDescription | string | null | Recalled product description |
productQuantity | string | null | Quantity distributed |
reasonForRecall | string | null | Root cause / reason for recall |
codeInfo | string | null | UDI, lot, batch, or serial numbers |
openfda | object | null | Cross-referenced openFDA device/drug identifiers when present |
510(k) Clearances (device_510k)
| Field | Type | Description |
|---|---|---|
dataset | string | device_510k |
kNumber | string | null | 510(k) number (e.g. K262005) |
deviceName | string | null | Cleared device trade name |
applicant | string | null | Applicant company name |
contact | string | null | Submission contact person |
city / state / country | string | null | Applicant location |
decisionDate | string | null | FDA decision date (YYYY-MM-DD) |
decisionDescription | string | null | Decision description (e.g. Substantially Equivalent) |
dateReceived | string | null | Submission receipt date (YYYY-MM-DD) |
productCode | string | null | 3-letter FDA product code |
advisoryCommitteeDescription | string | null | Medical specialty advisory committee |
regulationNumber | string | null | 21 CFR regulation number |
clearanceType | string | null | Traditional, Special, or Abbreviated |
statementOrSummary | string | null | Summary or Statement |
fdaUrl | string | null | Direct CDRH 510(k) link |
Sample output row (Enforcement)
{"dataset": "device_enforcement","recallNumber": "Z-3183-2026","eventId": "99634","productType": "Devices","classification": "Class II","status": "Ongoing","recallingFirm": "Stryker Sustainability Solutions","city": "Tempe","state": "AZ","country": "United States","reportDate": "2026-09-23","recallInitiationDate": "2026-08-19","centerClassificationDate": "2026-09-16","terminationDate": null,"voluntaryMandated": "Voluntary: Firm initiated","initialFirmNotification": "N/A","distributionPattern": "US Nationwide distribution...","productDescription": "REF:2B5ST Ethicon Endo-Surgery, Inc. XCEL BLADELESS TROCAR W/OPTIVIEW TECHNOLOGY & SLEEVE 5MM X 75MM","productQuantity": "2838 units","reasonForRecall": "Reusable access port system may crack or seperate during use.","codeInfo": "UDI: (01)00885825017231/ Lots: 16188647 16210212...","openfda": null}
How pricing works
Pay per result. You only pay for rows returned.
Data source and terms
Data is pulled from the U.S. Food and Drug Administration's openFDA API (https://api.fda.gov), updated weekly from FDA Recall Enterprise System (RES) Enforcement Reports and regularly from the CDRH 510(k) database. openFDA data is provided under the openFDA license and Terms of Service.
openFDA disclaimer: Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.
Data provided by the U.S. Food and Drug Administration (https://open.fda.gov).
This Actor is an independent tool. It is not affiliated with, endorsed by or an official product of the FDA or openFDA. It reshapes openFDA records (selected fields, renamed keys, blank values returned as null) without changing their content; check the official FDA record before acting on it.
Limits and FAQ
- Why must enforcement
dateFrombe>= 2012-06-20? openFDA's enforcement datasets (device/enforcement,drug/enforcement,food/enforcement) begin coverage on June 20, 2012; earlier dates are rejected up front with a clear validation message (device_510kcovers clearances back to 1976). - How are large result sets (> 25,000 rows) paginated? openFDA caps
skipat 25,000, so this Actor useslimit=1000and follows theLink: <...>; rel="next"(search_after) cursor header.
Changelog
-
v0.1.2 — Added the openFDA disclaimer and a non-affiliation notice.
-
v0.1.1 — Results are sorted newest first (report date for recalls, decision date for 510(k)). Blank text fields are returned as null.
-
v0.1 — Initial release supporting
device_enforcement,drug_enforcement,food_enforcement, anddevice_510kwithsearch_aftercursor pagination.