FDA Recalls & 510(k) Clearances Scraper (openFDA API) avatar

FDA Recalls & 510(k) Clearances Scraper (openFDA API)

Pricing

from $2.00 / 1,000 fda records

Go to Apify Store
FDA Recalls & 510(k) Clearances Scraper (openFDA API)

FDA Recalls & 510(k) Clearances Scraper (openFDA API)

FDA medical device, drug and food recalls (enforcement reports) and 510(k) device clearances from the public openFDA API. Filter by class, status, keyword, firm, state and date. Newest first. Regulatory monitoring and medtech competitive intelligence. No API key needed.

Pricing

from $2.00 / 1,000 fda records

Rating

0.0

(0)

Developer

John

John

Maintained by Community

Actor stats

0

Bookmarked

2

Total users

1

Monthly active users

a day ago

Last modified

Categories

Share

FDA Recalls (Device, Drug, Food) & 510(k) Clearances Scraper — openFDA API

Extract official U.S. Food and Drug Administration (FDA) Enforcement Recall Reports (device_enforcement, drug_enforcement, food_enforcement) and 510(k) Premarket Notification Clearances (device_510k) from the official openFDA JSON APIs (api.fda.gov).

Supports deep cursor pagination via the Link: <...>; rel="next" (search_after) response header to bypass openFDA's 25,000 skip cap, normalizes all FDA YYYYMMDD dates to ISO YYYY-MM-DD, and works out of the box without an API key (or accepts an optional openFdaApiKey for 120,000 requests/day).

Who it's for

  • Regulatory affairs, quality assurance (QA/RA) & compliance teams monitoring Class I, Class II, and Class III recalls across medical devices, pharmaceuticals, and food products
  • MedTech commercial, competitive intelligence & BD teams tracking newly cleared 510(k) devices (kNumber, deviceName, applicant, contact, productCode, regulationNumber)
  • Supply chain, hospital procurement, legal & risk management analysts auditing vendor recall histories and UDI/lot code notices (codeInfo)

Input

By default, the Actor pulls up to 200 Class I and Class II medical device enforcement recalls reported in the past 90 days.

{
"dataset": "device_enforcement",
"classifications": ["Class I", "Class II"],
"statuses": ["Ongoing"],
"keywords": ["catheter", "infusion pump"],
"firmName": "",
"states": ["CA", "MN"],
"dateFrom": "2026-07-25",
"dateTo": "2026-10-23",
"maxItems": 200
}
FieldTypeDefaultDescription
datasetstring"device_enforcement"device_enforcement, drug_enforcement, food_enforcement, or device_510k.
classificationsarray["Class I", "Class II"]Hazard classifications (Class I, Class II, Class III) — applies to enforcement datasets only.
statusesarray[] (all)Recall statuses (Ongoing, Completed, Terminated, Pending) — enforcement only.
keywordsarray of strings[] (all)Matched in product_description or reason_for_recall (enforcement) or device_name (device_510k).
firmNamestring"" (all)Matched against recalling_firm (enforcement) or applicant (device_510k).
statesarray of strings[] (all)2-letter US state codes (e.g. ["CA", "MN"]).
dateFromstring (YYYY-MM-DD)today - 90 daysStart of report_date (enforcement; minimum 2012-06-20) or decision_date (device_510k).
dateTostring (YYYY-MM-DD)todayEnd of report_date or decision_date.
openFdaApiKeystring (secret)""Optional free openFDA API key (increases quota from 1,000/day to 120,000/day).
maxItemsinteger200Maximum number of rows to output.

Output

Every output row includes a dataset field identifying the source dataset.

Enforcement datasets (device_enforcement, drug_enforcement, food_enforcement)

FieldTypeDescription
datasetstringdevice_enforcement, drug_enforcement, or food_enforcement
recallNumberstring | nullFDA recall number (e.g. Z-3183-2026)
eventIdstring | nullFDA recall event ID
productTypestring | nullDevices, Drugs, or Food
classificationstring | nullClass I, Class II, or Class III
statusstring | nullOngoing, Completed, Terminated, or Pending
recallingFirmstring | nullRecalling firm name
city / state / countrystring | nullRecalling firm location
reportDatestring | nullEnforcement report publication date (YYYY-MM-DD)
recallInitiationDatestring | nullRecall initiation date (YYYY-MM-DD)
centerClassificationDatestring | nullFDA classification date (YYYY-MM-DD)
terminationDatestring | nullRecall termination date (YYYY-MM-DD)
voluntaryMandatedstring | nullVoluntary vs. FDA-mandated status
initialFirmNotificationstring | nullInitial firm notification method
distributionPatternstring | nullGeographic distribution pattern
productDescriptionstring | nullRecalled product description
productQuantitystring | nullQuantity distributed
reasonForRecallstring | nullRoot cause / reason for recall
codeInfostring | nullUDI, lot, batch, or serial numbers
openfdaobject | nullCross-referenced openFDA device/drug identifiers when present

510(k) Clearances (device_510k)

FieldTypeDescription
datasetstringdevice_510k
kNumberstring | null510(k) number (e.g. K262005)
deviceNamestring | nullCleared device trade name
applicantstring | nullApplicant company name
contactstring | nullSubmission contact person
city / state / countrystring | nullApplicant location
decisionDatestring | nullFDA decision date (YYYY-MM-DD)
decisionDescriptionstring | nullDecision description (e.g. Substantially Equivalent)
dateReceivedstring | nullSubmission receipt date (YYYY-MM-DD)
productCodestring | null3-letter FDA product code
advisoryCommitteeDescriptionstring | nullMedical specialty advisory committee
regulationNumberstring | null21 CFR regulation number
clearanceTypestring | nullTraditional, Special, or Abbreviated
statementOrSummarystring | nullSummary or Statement
fdaUrlstring | nullDirect CDRH 510(k) link

Sample output row (Enforcement)

{
"dataset": "device_enforcement",
"recallNumber": "Z-3183-2026",
"eventId": "99634",
"productType": "Devices",
"classification": "Class II",
"status": "Ongoing",
"recallingFirm": "Stryker Sustainability Solutions",
"city": "Tempe",
"state": "AZ",
"country": "United States",
"reportDate": "2026-09-23",
"recallInitiationDate": "2026-08-19",
"centerClassificationDate": "2026-09-16",
"terminationDate": null,
"voluntaryMandated": "Voluntary: Firm initiated",
"initialFirmNotification": "N/A",
"distributionPattern": "US Nationwide distribution...",
"productDescription": "REF:2B5ST Ethicon Endo-Surgery, Inc. XCEL BLADELESS TROCAR W/OPTIVIEW TECHNOLOGY & SLEEVE 5MM X 75MM",
"productQuantity": "2838 units",
"reasonForRecall": "Reusable access port system may crack or seperate during use.",
"codeInfo": "UDI: (01)00885825017231/ Lots: 16188647 16210212...",
"openfda": null
}

How pricing works

Pay per result. You only pay for rows returned.

Data source and terms

Data is pulled from the U.S. Food and Drug Administration's openFDA API (https://api.fda.gov), updated weekly from FDA Recall Enterprise System (RES) Enforcement Reports and regularly from the CDRH 510(k) database. openFDA data is provided under the openFDA license and Terms of Service.

openFDA disclaimer: Do not rely on openFDA to make decisions regarding medical care. While we make every effort to ensure that data is accurate, you should assume all results are unvalidated. We may limit or otherwise restrict your access to the API in line with our Terms of Service.

Data provided by the U.S. Food and Drug Administration (https://open.fda.gov).

This Actor is an independent tool. It is not affiliated with, endorsed by or an official product of the FDA or openFDA. It reshapes openFDA records (selected fields, renamed keys, blank values returned as null) without changing their content; check the official FDA record before acting on it.

Limits and FAQ

  • Why must enforcement dateFrom be >= 2012-06-20? openFDA's enforcement datasets (device/enforcement, drug/enforcement, food/enforcement) begin coverage on June 20, 2012; earlier dates are rejected up front with a clear validation message (device_510k covers clearances back to 1976).
  • How are large result sets (> 25,000 rows) paginated? openFDA caps skip at 25,000, so this Actor uses limit=1000 and follows the Link: <...>; rel="next" (search_after) cursor header.

Changelog

  • v0.1.2 — Added the openFDA disclaimer and a non-affiliation notice.

  • v0.1.1 — Results are sorted newest first (report date for recalls, decision date for 510(k)). Blank text fields are returned as null.

  • v0.1 — Initial release supporting device_enforcement, drug_enforcement, food_enforcement, and device_510k with search_after cursor pagination.