Product Recall Monitor (CPSC, NHTSA, FDA, EU) avatar

Product Recall Monitor (CPSC, NHTSA, FDA, EU)

Pricing

from $5.00 / 1,000 recall records

Go to Apify Store
Product Recall Monitor (CPSC, NHTSA, FDA, EU)

Product Recall Monitor (CPSC, NHTSA, FDA, EU)

Search consumer product, vehicle, food, drug and device recalls from CPSC, NHTSA, FDA and EU Safety Gate open data, check VINs, and watch brands for new recalls.

Pricing

from $5.00 / 1,000 recall records

Rating

0.0

(0)

Developer

Chris O'Byrne

Chris O'Byrne

Maintained by Community

Actor stats

0

Bookmarked

2

Total users

1

Monthly active users

a day ago

Last modified

Share

What does Product Recall Monitor do?

Product Recall Monitor watches official recall notices across four public sources and returns the same clean fields for each: the US Consumer Product Safety Commission (CPSC), the FDA (through openFDA), the EU Safety Gate rapid alert system for non-food products, and the US National Highway Traffic Safety Administration (NHTSA). Give it your brands and keywords once, schedule it, and each run returns only the recalls it has not shown you before.

It has three modes:

  • Watchlist: a list of brands or keywords. Each run returns only new recalls since the previous run, so you can schedule it daily or weekly and act on what is new.
  • Recall search: find recalls by keyword, brand, product category, agency and date range, across all selected agencies in one dataset.
  • VIN check: a secondary mode that decodes up to 200 VINs and lists the NHTSA recall campaigns filed for each vehicle's make, model and model year.

Every recall comes back as one row with a recall ID, agency, date, product, brand, hazard, remedy, manufacturer, units affected, model or UPC where the source gives one, country, and a link to the official source. Results are available as JSON, CSV, Excel or through the Apify API.

Who is it for?

Retailers and marketplace sellers who must check their catalog against recalls, product compliance and quality teams, insurers and claims teams, fleet and used-car operators, recall-notification apps, and researchers who need recall data across agencies without writing four integrations.

How to use it

  1. Open the Actor and choose a Mode.
  2. For recall search, enter keywords and or brands, pick the agencies, and set Max results. For NHTSA also enter a vehicle make and model year, or a campaign number.
  3. For a watchlist, enter the terms and a Watchlist name, run it once, then add a schedule in Apify to run it again.
  4. For VIN check, paste your VINs, one per line.
  5. Download the dataset or call it through the API.

Input examples

Recall search (the default prefill):

{
"mode": "recall-search",
"keywords": ["stroller"],
"agencies": ["cpsc", "fda", "eu_safety_gate"],
"daysBack": 365,
"maxResults": 20
}

Watchlist:

{
"mode": "watchlist",
"watchlistTerms": ["stroller", "Graco", "crib"],
"agencies": ["cpsc", "fda", "eu_safety_gate"],
"watchlistName": "baby-products",
"watchlistLookbackDays": 14
}

NHTSA search by vehicle:

{
"mode": "recall-search",
"agencies": ["nhtsa"],
"vehicleMake": "Ford",
"vehicleModel": "F-150",
"vehicleYear": 2022,
"maxResults": 10
}

VIN check:

{ "mode": "vin-check", "vins": ["1FTFW1E50NFA00001", "1HGCM82633A004352"] }

Output example

{
"record_type": "recall",
"recall_id": "26639",
"agency": "CPSC",
"date": "2026-07-23",
"title": "Peony Design Recalls Personalized Baby Bibs and Stroller Bags Due to Risk of Serious Injury or Death from Choking Hazard",
"product": "Personalized Baby Bibs and Stroller Bags",
"brand": null,
"hazard": "The snap can detach from the recalled bibs and stroller bags, posing a risk of serious injury or death from a choking hazard to young children.",
"remedy": "Consumers should take the recalled baby bibs and stroller bags away from children immediately, stop using them, and contact Peony Design to receive a full refund. Consumers will be asked to discard the recalled baby bibs and stroller bags.",
"remedy_type": "Refund",
"manufacturer": "Peony Design Co., of Howell, MI",
"units": "About 52",
"model": null,
"upc": null,
"category": null,
"country": "United States",
"source_url": "https://www.cpsc.gov/Recalls/2026/Peony-Design-Recalls-Personalized-Baby-Bibs-and-Stroller-Bags-Due-to-Risk-of-Serious-Injury-or-Death-from-Choking-Hazard"
}

Fields the source does not publish are returned as null. Some rows carry extra agency fields, for example FDA classification and status, EU risk_level and notifying_country, and NHTSA park_it. VIN check rows contain the decoded make, model, model year, trim, body class, plant country, and a recalls list.

How the dates and fields are defined

  • CPSC: date is the recall date. brand is read from an "X-branded" phrase in the description when there is one, otherwise null. manufacturer falls back to the importer or distributor when no manufacturer is listed.
  • NHTSA: date is the date the manufacturer reported the campaign. One row is returned per campaign, with the matching models merged. units is looked up per campaign.
  • FDA: date is the enforcement report date, which is when the recall appears in openFDA. recall_initiation_date is when the firm began it. FDA does not publish a remedy field, so remedy is null. UPCs are read from the product description when it contains one.
  • EU Safety Gate: date is the publication date of the weekly report that contains the alert. remedy holds the measures taken. manufacturer and units are not published.

Pricing

You pay per event. You pay only these event prices; platform usage is not billed to you separately.

EventPriceWhen it is charged
Actor start$0.00005Once per run (Apify platform event)
Recall record$0.005Per recall row returned in recall search or watchlist mode
VIN check$0.01Per VIN that was decoded and checked. VINs that are invalid or cannot be decoded are not charged
Watchlist run with new recalls$0.02Per watchlist run that returns at least one new recall. Runs with nothing new are not charged

Examples: the default prefill (up to 20 recalls) costs at most $0.10. A VIN check of 50 vehicles costs $0.50. A daily watchlist that finds 3 new recalls costs $0.035 that day and nothing on days with no news. You can set a maximum charge per run in the run options and the Actor stops at that limit.

Data sources and licences

  • CPSC Recalls API, saferproducts.gov. US government public information. The CPSC API page does not publish a numeric rate limit or separate licence terms.
  • NHTSA recalls API (api.nhtsa.gov) and vPIC VIN decoder (vpic.nhtsa.dot.gov). US government public information. NHTSA says vPIC applies automated traffic rate control.
  • openFDA enforcement reports (api.fda.gov). Content is dedicated to the public domain under CC0 1.0 unless noted; the openFDA terms apply. Data provided by the U.S. Food and Drug Administration (https://open.fda.gov). openFDA limits unauthenticated use to 240 requests per minute and 1,000 per day per IP address. You can enter your own free openFDA key to raise the daily limit. The openFDA disclaimer applies: do not rely on this data to make decisions about medical care.
  • EU Safety Gate weekly report XML, published by the European Commission as open data. The data.europa.eu catalogue lists this XML distribution under CC0 1.0. Other Safety Gate content is covered by the Commission reuse notice.

The Actor sends a descriptive User-Agent with a contact address, spaces its requests (at most about 3 per second per host, less for some hosts), retries politely on errors and honors Retry-After. It does not log in, use proxies or work around any limit.

This Actor is not affiliated with, endorsed by or sponsored by CPSC, NHTSA, FDA, the European Commission or any other agency named here. Agency names are used only to describe the data source.

Personal data

The Actor returns recall notices published by agencies. It does not output consumer contact details, retailer lists or street addresses. E-mail addresses and non toll-free phone numbers inside agency text are replaced with placeholders. Manufacturer names are business names as the agency published them. VINs you submit are processed only to call NHTSA and are written only to your own dataset.

FAQ

Is a VIN check the same as an open recall check? No. NHTSA does not offer a public per-VIN API that says whether a recall repair was already done. The VIN check decodes the VIN and lists every NHTSA campaign filed for that make, model and model year. Confirm repair status with the manufacturer or on nhtsa.gov/recalls.

Why does NHTSA need a make and model year? The NHTSA recalls API only searches by make, model and model year or by campaign number. It has no keyword search. If you give a make and year without a model, up to 40 models are searched.

How does the watchlist know what is new? It stores the IDs it has returned and the last successful run date per agency in a key-value store named product-recall-monitor-state in your account. Change the Watchlist name to keep separate lists. Turn on Reset watchlist state to start over.

How long does a run take? CPSC, FDA and NHTSA answer in seconds. EU Safety Gate is read from weekly report files, so a 365 day search reads about 50 files and takes about a minute.

Why did a source return nothing? No recall in the date range matched your terms, or the source was unreachable. The key-value store record RUN_SUMMARY shows what each source returned and any error. If every selected source fails, the run fails and nothing is charged.

Limitations

  • Keyword matching is plain text matching. CPSC matches on title, product name and description; FDA on product description, reason and firm name; EU Safety Gate on alert text.
  • The EU Safety Gate data does not include manufacturer or units, and its dates are weekly report dates.
  • Source data can lag the agencies' own websites and can contain errors. Always check the linked official notice before acting.
  • openFDA allows 1,000 unauthenticated requests per day per IP address. Add your own key if you hit it.

Support

Use the Issues tab of this Actor to report a problem or request a source or field. Include the run ID and your input.