FlightMortem — Drone Flight Log Analyzer avatar

FlightMortem — Drone Flight Log Analyzer

Pricing

from $15.00 / 1,000 bounds-clamped pid & filter tune diffs

Go to Apify Store
FlightMortem — Drone Flight Log Analyzer

FlightMortem — Drone Flight Log Analyzer

Inspect ArduPilot DataFlash (.bin), PX4 ULog (.ulg or .ulog) and Betaflight Blackbox (.bbl) flight logs. Estimate battery internal resistance or find vibration peaks when the recording contains the needed samples. Try the built-in PX4 battery example.

Pricing

from $15.00 / 1,000 bounds-clamped pid & filter tune diffs

Rating

0.0

(0)

Developer

Raymond de Oliveira

Raymond de Oliveira

Maintained by Community

Actor stats

0

Bookmarked

1

Total users

0

Monthly active users

4 hours ago

Last modified

Features

Limited permissions

Share

FlightMortem

Inspect ArduPilot DataFlash (.bin), PX4 ULog (.ulg or .ulog) and Betaflight Blackbox (.bbl) flight logs, or estimate battery internal resistance from recorded voltage and current.

Try a PX4 ULog

Open the free PX4 ULog battery example. Select Try for free, then start the copied task in Apify Console. The 255-byte synthetic log is already included. The dataset shows two rows.

ResultValue
File format and durationpx4_ulog, 3 s
Battery resistance and sample count25 mΩ from 4 readings

Both operations use zero paid tool events. The PX4 battery results dataset view shows the fields above. The Full results view includes the underlying structured data.

Try the four-sample battery check

Start the Actor with the prefilled input, or paste this into the JSON input editor. The current rises by 10 A per sample as the voltage drops by 0.25 V.

{
"tool": "fm_power_health",
"arguments": {
"telemetry": {
"battery": [
{ "t_s": 0, "voltage_v": 25.0, "current_a": 0 },
{ "t_s": 1, "voltage_v": 24.75, "current_a": 10 },
{ "t_s": 2, "voltage_v": 24.5, "current_a": 20 },
{ "t_s": 3, "voltage_v": 24.25, "current_a": 30 }
]
}
}
}

Open the default dataset when the run finishes. Its single row reports data.r_int_mohm of 25 and data.sample_count of 4. The battery check incurs zero tool charge events.

Use your own flight data

To inspect your log, send base64-encoded file bytes in log_base64 to fm_inspect_log. The hosted limit is 1,572,864 decoded bytes. For fm_power_health, send a log that includes battery voltage and current or send the JSON readings shown above. Gyro spectrum analysis needs IMU samples. Apify processes the records you send. Use the synthetic sample to explore the results without uploading your own flight data.

For a batch, replace the entire input with a JSON object containing only a calls array. Put one { "tool": ..., "arguments": ... } object in that array for each calculation. Add an id to each object to identify its result in the dataset.

See the FlightMortem GitHub quickstart for curl and MCP setup, or download the synthetic ULog.