FAERS Adverse Events Scraper - FDA Drugs and MAUDE Devices avatar

FAERS Adverse Events Scraper - FDA Drugs and MAUDE Devices

Pricing

from $3.00 / 1,000 adverse event reports

Go to Apify Store
FAERS Adverse Events Scraper - FDA Drugs and MAUDE Devices

FAERS Adverse Events Scraper - FDA Drugs and MAUDE Devices

Search openFDA FAERS drug reports and MAUDE device events, export reactions, seriousness, demographics and trend counts, and connect suspect medicines to drug labels and recalls.

Pricing

from $3.00 / 1,000 adverse event reports

Rating

0.0

(0)

Developer

SR

SR

Maintained by Community

Actor stats

0

Bookmarked

2

Total users

1

Monthly active users

15 days ago

Last modified

Features

Limited permissions

Share

FAERS Adverse Events Scraper

Search FAERS drug adverse events and FDA MAUDE medical device reports, export individual cases or trend counts, and connect suspect medicines to published labels and recalls. Both databases come from the FDA's public openFDA service.

Use this Actor to prepare pharmacovigilance datasets, monitor reported product problems, compare reporting patterns, or assemble a medicine dossier. Drug and device reports share normalized fields while retaining their original source identifiers. Each delivered row identifies its database and record type, so downstream tables can distinguish cases from aggregate buckets.

FAERS input and search options

Choose source: drug for FAERS, the default, or source: device for MAUDE. Supply a report number, product names, a reaction, a manufacturer, countries, seriousness, or a date range. Names within a list are combined with OR; different criteria are combined with AND. Drug names are searched in reported medicinal product names and harmonized brand and generic names. Device names are searched in generic and brand names.

This real report lookup is a small starting point:

{"report_id":"10004089","max_items":1}

The report contains AMPYRA among the suspect medicines. To look up a device report, use:

{"source":"device","report_id":"2649622-2020-08294","max_items":1}

For a drug search, drug_names: ["metformin"], reaction: "headache", date_from: "2024-01-01" and date_to: "2024-12-31" are supported. Dates are inclusive and must be calendar dates. The default date field is receipt date. Devices additionally support date_field: event. Drug event dates are unavailable in this dataset, so that combination is rejected.

ndc accepts a hyphenated package NDC such as 0259-5010-60. A shorter product NDC is rejected with an explanation. Names cannot contain quotation marks, backslashes or control characters. These checks prevent broken expressions from looking like empty searches. Supply up to 100 names or identifiers per list. max_items defaults to 100 and supports 1 to 2000 delivered rows across continuation requests.

Output and interpretation

Case rows carry _type and record_type equal to adverse_event. They include report_id, product_type, fetched_at, position, receipt and event dates where available, products, reactions, seriousness, country, patient age in years, patient sex and manufacturer. Missing values remain null or empty lists. Partial dates retain the precision supplied by the source.

Drug rows include all reported medicines in drugs, their suspect, concomitant or interacting roles, dosage and indication, harmonized names, package NDCs and SPL set IDs. The top-level products list contains suspect medicines only. reaction_outcomes preserves the original outcome code alongside each reaction. These codes distinguish recovered, recovering, not recovered, recovered with sequelae, fatal and unknown outcomes. A reported reaction and outcome do not establish causation.

Device rows include device names, manufacturer, model, catalog and lot numbers, product codes, source event type, patient problems and available narrative. Narrative text is limited to 20000 characters in the normalized row. outputMode: full additionally includes the original report as raw; the default slim omits that original object.

patient_weight preserves the published weight as text. FAERS documents kilograms, so a supplied weight has patient_weight_unit: "kg" and a numeric patient_weight_kg. MAUDE does not document the unit; both patient_weight_unit and patient_weight_kg are null for device reports. No weight conversion is inferred. Missing reactions or suspect product names are null. FAERS non-serious reports have seriousness: []; serious reports without published criteria have null. MAUDE only supplies the death criterion; other device event types have null criteria.

Here is a real delivered row, the device report 2649622-2020-08294, with the long narrative text left out:

{
"_type": "adverse_event",
"record_type": "adverse_event",
"report_id": "2649622-2020-08294",
"product_type": "device",
"url": null,
"received_date": "2020-04-27",
"event_date": "2020-04-07",
"serious": false,
"seriousness": null,
"reactions": ["No Known Impact Or Consequence To Patient"],
"products": ["CAPSUREFIX NOVUS LEAD MRI SURESCAN"],
"patient_age_years": 71,
"patient_sex": null,
"patient_weight": "108",
"patient_weight_unit": null,
"patient_weight_kg": null,
"country": "US",
"manufacturer": "MPRI",
"report_number": "2649622-2020-08294",
"mdr_report_key": "10000007",
"event_type": "Malfunction",
"report_source": "Manufacturer report",
"product_problems": ["Under-Sensing", "Under-Sensing"],
"devices": [
{
"brand_name": "CAPSUREFIX NOVUS LEAD MRI SURESCAN",
"generic_name": "ELECTRODE, PACEMAKER, PERMANENT",
"manufacturer": "MPRI",
"model_number": "5076-52",
"catalog_number": "5076-52",
"lot_number": null,
"product_code": "DTB",
"device_class": "3",
"udi_di": null
}
]
}

Every value above is delivered exactly as shown; only the narrative text and the collection bookkeeping fields (source, authority, row_key, fetched_at, position, enrichment_eligible) are omitted for readability. A drug row for report 10004089 carries the same case fields plus seriousness: ["hospitalization", "other"], the suspect medicines AMPYRA and BUSPAR, the patient's age of 46 years, the manufacturer Merz Pharmaceuticals, LLC, sixteen reactions with their outcome codes, and for each medicine its roles, dosage, indication, brand and generic names, package NDCs and SPL set IDs.

Use cases

  • Signal screening for pharmacovigilance teams. Pull every FAERS report naming a substance, brand or manufacturer inside a date window, filter on seriousness and reaction term, and review outcomes per case instead of per spreadsheet download.
  • Brand safety monitoring. Re-run a bounded receipt-date range each period to watch reports that mention your product or a competitor's, and keep the delivered rows as the dated record of what was reported when.
  • Medical device vigilance. MAUDE case rows carry device manufacturer, model and catalog numbers, lot numbers, product codes, source event type and patient problems, which supports complaint review next to your own quality records.
  • Medicine dossier. With enrich: true, a suspect medicine's reports arrive with their published label and its recall matches attached, keyed by SPL set ID and package NDC - one compact view per medicine rather than four separate lookups.
  • Trend questions without case transfer. Count reports per receipt date, country, seriousness or reaction term, so a "how many were reported in June" question costs a handful of buckets instead of thousands of case rows.
  • Warehouse loading. Export the default dataset as JSON or CSV with normalized field names, and stop maintaining separate parsers for the drug quarterly files and the device interface.

Trend counts

Set count to request aggregate buckets instead of case reports. For drugs, useful fields include receivedate, occurcountry, serious and patient.reaction.reactionmeddrapt.exact. For devices, examples include date_received, date_of_event and event_type.exact. Only documented fields for the selected database are accepted. Text fields automatically receive the .exact suffix, which is required for these aggregations; you can also supply it explicitly. For example, occurcountry becomes occurcountry.exact and event_type becomes event_type.exact. The returned count_field contains that canonical name, and buckets preserve whole phrases. Date fields and the numeric serious field do not accept .exact. The device field reporter_country_code cannot be counted; use country_codes to filter device reports by country. Unsupported forms are rejected with an input error before querying the database.

Count rows have _type and record_type equal to event_count, with term, count and count_field. An explicitly empty source value remains an empty term; for example, device reports with an unreported manufacturer can form a real bucket with term: "". This bucket is a real delivered row, one of the counts for metformin reports with the reaction headache in January 2024:

{
"_type": "event_count",
"record_type": "event_count",
"product_type": "drug",
"count_field": "receivedate",
"term": "2024-01-02",
"count": 3
}

Date buckets use ISO formatting. Count mode supports at most 999 returned buckets and cannot request medicine enrichment. A bucket is one output row regardless of the number of source reports it summarizes. Counts describe reports received by the system; they are not patient incidence rates or comparative risk estimates.

If the source returns more buckets than max_items, the delivered series is truncated: partial is true and warnings explains the cap. next_cursor is null because no continuation is available for omitted count buckets. Increase max_items or narrow the query to obtain the full series; a null cursor alone does not establish completeness.

Text counts request one extra bucket to detect truncation; that check bucket is neither delivered nor charged. At max_items: 999, the source limit leaves no room for this check. A response containing exactly 999 source buckets therefore also sets partial: true and warns that additional terms may be omitted. Narrow the query to verify completeness.

Medicine labels and recalls

Set enrich: true on a drug report query to attach label and recalls. The label lookup uses the first available suspect SPL set ID. The recall lookup uses the available suspect package NDCs and returns up to 100 matches per report, with a warning if the source has more. The label supplies its stable label ID, brand name and application number. Recall matches supply recall number, classification and recall date.

The API response reports coverage per response in enrichment. The Apify run output recomputes eligible_count, label_matches and recall_matches across all delivered pages after the delivery cap. Divide each match count by eligible_count for the run match rate; a zero denominator means no eligible reports were delivered.

Coverage is incomplete because not every report has harmonized identifiers. enrichment reports the number of eligible delivered cases, label matches, recall matches and match rates. A missing join key or unmatched label produces an explicit warning. An empty recall list means no matching recall was returned for those identifiers at retrieval time. It does not establish product safety. Matching is limited to the identifiers reported in the source; the Actor does not infer equivalent medicines.

Unsafe source identifiers containing quotes, backslashes or control characters are skipped with a warning. If the source rejects an enrichment query, the case row is retained and subsequent reports continue. Inspect partial and warnings for incomplete enrichment.

What else exists for FAERS and MAUDE data

Four options a buyer usually weighs:

  • The FDA public dashboards for FAERS and MAUDE. Good for looking up one report or reading a chart, but they are browsing interfaces: exporting a filtered set of case rows for your own table means copying by hand.
  • The openFDA service itself. Free, documented, and the same source this Actor reads. It serves one database per endpoint, returns the source's own field names and codes, and does not attach label and recall matches to the report you just fetched. The drug-plus-device normalization, the date splitting for large queries and the enrichment joins are the work you avoid here.
  • The quarterly FAERS file drops. Complete and bulk, but files you download and parse yourself, with no query interface and no equivalent device bundle in the same shape. For a one-off full-database dump they are the better fit.
  • Single-database scrapers. Most cover FAERS or MAUDE, case rows only. This Actor covers both databases behind one input contract, adds trend count buckets, and joins suspect medicines to labels and recalls in the same run - the dossier view the other options leave you to assemble.

The trade-off in the other direction: this Actor is a query API with a delivery cap, not a full historical archive.

Pagination and completeness

The Actor follows continuation tokens automatically while respecting max_items. API clients can pass next_cursor back as cursor with the original input. Keep all other values unchanged. Positions continue across pages, and identifiers are deduplicated by default. exclude_duplicates: true also excludes drug reports explicitly marked duplicate by the source.

Large queries are split into non-overlapping receipt-date ranges before reaching the source pagination limit. If a single date still exceeds that limit, the response warns that a narrower query is needed. Inspect partial, warnings and next_cursor before treating an export as complete. Use a bounded date range for repeatable monitoring, since upstream data can change between requests.

Pricing and delivery limits

The Actor uses delivered-row events: adverse_event for case reports and event_count for count buckets. Each delivered row belongs to exactly one event. Empty results incur no row charge. Labels and recall matches are attached to their case row and are not separate output events. Check the current Actor pricing tab for the actual event prices.

Non-paying users are limited to 10 delivered rows per run. Paying users can request up to 2000 case rows, or 999 count buckets, using the same input fields. The volume cap applies across continuation requests. Export the default dataset as JSON or CSV; use the run output for collection warnings and enrichment coverage.

FAQ

Does a FAERS report prove a medicine caused an adverse event?

No. Reports can be incomplete, duplicated, unverified or influenced by reporting practices. This dataset supports investigation and reporting analysis. It does not establish causation, incidence, treatment suitability or a product safety ranking.

Can I retrieve both drug and device reports in one run?

Choose one database per run. Both share the same case fields, but their source-specific search criteria differ. Run separate searches and join exported tables using the database and report identifier.

Why is there no label or recall match for a medicine?

Some reports lack SPL set IDs or package NDCs, and published datasets have different coverage. Review the warnings and match counts. Missing matches should remain missing rather than being interpreted as evidence of no safety issue.

How current are the records?

The Actor returns the records currently exposed by the FDA service. Reporting and publication delays apply. fetched_at records collection time; receipt dates refer to the source report and are not the collection timestamp.

Can I use the terminology without checking its terms?

Review the FDA data terms and applicable MedDRA licensing conditions for your intended use. Reaction terms are reproduced from the public report data. This Actor does not provide a separate terminology license or medical advice.