Sourcing Recall Evidence Checker avatar

Sourcing Recall Evidence Checker

Pricing

$20.00 / 1,000 matches

Go to Apify Store
Sourcing Recall Evidence Checker

Sourcing Recall Evidence Checker

Check product model numbers against US CPSC recall notices before you buy or list. Returns only notices where your number appears, with the quoted text, recall date, hazard, remedy and official link. No match, no charge.

Pricing

$20.00 / 1,000 matches

Rating

0.0

(0)

Developer

X-man Tools

X-man Tools

Maintained by Community

Actor stats

0

Bookmarked

2

Total users

1

Monthly active users

a month ago

Last modified

Categories

Features

Limited permissions

Share

Sourcing Recall Evidence Checker - US CPSC recall match by model number

Before you buy or list a product for the US market, check whether its model number appears in a US Consumer Product Safety Commission (CPSC) recall notice. Give up to 20 model numbers (and optionally a brand); the Actor returns only the recalls whose notice text contains that exact number, with the quoted evidence and the link to the official notice.

Built for importers, resellers and AI agents that screen sourcing candidates.

Input

FieldRequiredMeaning
modelNumbersyes1 to 20 model or product identification numbers. Each needs at least 4 letters or digits and at least one digit.
brandnoIf given, a match is confirmed only when the brand name also appears in the notice.
dateStart, dateEndnoLimit by recall date, YYYY-MM-DD.
maxMatchesnoUpper limit of results (default 20, at most 100).
{ "modelNumbers": ["20-01437"], "brand": "Stanley" }

Output

One dataset item per confirmed match (one model number in one recall):

{
"inputModel": "20-01437",
"inputBrand": "Stanley",
"matchBasis": "brand_and_number_string_in_notice",
"matchType": "exact_text",
"labelHint": "after a model/item/identification-number label in the same sentence",
"matchedText": "20-01437",
"matchedField": "Description",
"evidenceSnippet": "... Product Identification Number Switchback 12 ounces 20-01437 16 ounces 20-01436, 20-02211 ...",
"recallNumber": "25063",
"recallDate": "2024-12-12",
"title": "Stanley Recalls 2.6 Million Switchback and Trigger Action Travel Mugs Due to Burn Hazard",
"hazards": ["... posing a burn hazard."],
"remedies": ["... free replacement lid ..."],
"sourceUrl": "https://www.cpsc.gov/Recalls/2025/Stanley-Recalls-2-6-Million-Switchback-and-Trigger-Action-Travel-Mugs-Due-to-Burn-Hazard",
"retrievedAt": "2026-10-14T01:54:00Z"
}

The key-value store record OUTPUT always holds a run summary: ok, errorCode (NO_MATCH, INVALID_INPUT, SOURCE_ERROR), checkedModels, noMatchModels, failedModels, and reviewCandidates.

What a result means

A result states one checked fact: a string matching your number was found in this CPSC recall notice, and (if you gave one) the brand appears in the notice too. matchType says whether the string equals what you typed, ignoring letter case and spaces before or after your input (exact_text), or differs only in hyphens, dots, slashes, underscores or spaces (separators_ignored); matchedText is the notice's own spelling and evidenceSnippet quotes the place. The Actor does not decide what that string refers to or whether the recalled product is yours; read the notice at sourceUrl.

To keep useless hits out, a string found in the notice text is returned only when it follows a model, item or identification-number label in the same sentence (labelHint). This is a text heuristic, not a verified fact: a price or other number placed right after such a label can still pass, and a real model number written differently can be left out. In CPSC data the model numbers sit in the notice text (the structured model field was empty in all 1,204 recalls since 2024 we checked on 2026-10-14), so a text check is the only way to find them.

How it matches, and its limits

  • A match needs the same model number in the notice; one different character is not a match, and a longer identifier (AB-1234_REV2) is not matched by its first part (AB-1234). Product names alone are never matched.
  • Type the number as printed, hyphens included, and give the brand. The CPSC search finds text only as typed (2001437 does not find 20-01437). When you give brand, the Actor also reads the recalls that have the brand in their title and compares numbers with hyphens, dots, slashes, underscores and spaces ignored, so a differently written number can still be found. Without brand, a differently written number is missed.
  • With brand, the brand must also appear in the notice. If the number is found but the brand is not, the recall is listed under reviewCandidates in OUTPUT and is not written to the dataset.
  • Strings that look like a date, a phone number or a measurement, or that do not follow a label as described above, go to reviewCandidates in OUTPUT, not to the dataset. Some real model numbers will land there, so read reviewCandidates too.
  • No match is not a safety clearance. It only means these numbers were not found in CPSC notices for the dates given. Many notices describe products without model numbers; those cannot be found by this Actor.
  • US CPSC recalls only. No other country or agency, no unpublished defects. The physical product is not inspected.
  • Short or common numbers can coincide across unrelated products. Give the brand, and open sourceUrl before acting.
  • If the CPSC service cannot be read, the run reports SOURCE_ERROR and writes nothing to the dataset. It never substitutes sample data.

Pricing

Pay per event, one event only:

  • Match: $0.02 per match written to the dataset ($20 per 1,000 matches). Runs with no match, invalid input or a source error write nothing to the dataset, so nothing is charged. There is no start fee and no platform usage fee for users.

Example: checking 50 model numbers in one run that finds 1 match costs $0.02.

Data source

US CPSC Recall REST API (https://www.saferproducts.gov/RestWebServices/Recall), described at https://www.cpsc.gov/Recalls/CPSC-Recalls-Application-Program-Interface-API-Information. Data is read at run time (retrievedAt); nothing is cached. This Actor is not affiliated with or endorsed by the CPSC. One request per model number, plus one for the brand, two seconds apart.

Seller: X-man Tools