NYC LL84 Energy & Water Disclosure Data by Building avatar

NYC LL84 Energy & Water Disclosure Data by Building

Pricing

from $15.00 / 1,000 results

Go to Apify Store
NYC LL84 Energy & Water Disclosure Data by Building

NYC LL84 Energy & Water Disclosure Data by Building

Building energy benchmarking data for New York City, NY (LL84): energy use intensity, ENERGY STAR score, electricity, gas, GHG emissions, floor area, property type and compliance status per building, normalized across programs. Export to JSON, CSV or Excel.

Pricing

from $15.00 / 1,000 results

Rating

0.0

(0)

Developer

BuildingSignal

BuildingSignal

Maintained by Community

Actor stats

0

Bookmarked

2

Total users

1

Monthly active users

6 days ago

Last modified

Features

Limited permissions

Share

The full NYC Local Law 84 energy and water disclosure per building and year. Records carry BIN and borough identifiers, energy by fuel type, water use, emissions and the ENERGY STAR score reported through Portfolio Manager.

Here is one real record from this actor.

{
"buildingSignalId": "b9aef2a7050dffe6",
"jurisdiction": "New York City, NY",
"programName": "NYC Local Law 84 Benchmarking",
"country": "US",
"reportingYear": 2024,
"sourceRecordId": "8604",
"propertyName": "114",
"addressStreet": "114 West 47th st",
"city": "Manhattan",
"state": "NY",
"zip": "10036",
"latitude": 40.75831,
"longitude": -73.982504,
"parcelId": "1009990019",
"bin": "1022667",
"propertyType": "Financial Office",
"propertyTypeRaw": "Financial Office",
"grossFloorAreaSqft": 569516,
"yearBuilt": 1989,
"numberOfBuildings": 1,
"energyStarScore": 77,
"siteEuiKbtuSqft": 59.5,
"weatherNormalizedSiteEuiKbtuSqft": 62.1,
"sourceEuiKbtuSqft": 130.9,
"siteEnergyUseKbtu": 33889671,
"electricityKwh": 6216529,
"naturalGasTherms": 7743,
"districtSteamKbtu": 11904586,
"fuelOilKbtu": null,
"waterUseKgal": 5235.6,
"ghgEmissionsMtco2e": 3272.7,
"ghgIntensityKgco2eSqft": 5.75,
"complianceStatus": "compliant",
"complianceStatusRaw": "Report submitted",
"source": "NYC LL84 Energy & Water Disclosure",
"borough": "Manhattan",
"councilDistrict": 4,
"residentialUnits": null,
"largestUseType": "Financial Office",
"largestUseSqft": 368732,
"secondUseType": "Office",
"secondUseSqft": 149601,
"thirdUseType": "Other - Entertainment/Public Assembly",
"thirdUseSqft": 32668,
"electricityKbtu": 21210798.2,
"naturalGasKbtu": 774287,
"fuelOil2Kbtu": null,
"fuelOil4Kbtu": null,
"fuelOil56Kbtu": null,
"fuelOil1Kbtu": null,
"dieselKbtu": null,
"propaneKbtu": null,
"districtSteamKbtuRaw": 11904586.2,
"districtHotWaterKbtu": null,
"districtChilledWaterKbtu": null,
"nationalMedianSiteEui": 89.3,
"energyStarCertificationYears": "2001 (75), 2002 (76), 2003 (75), 2005 (77), 2006 (85), 2008 (86), 2010 (83), 2015 (86), 2016 (91), 2018 (87)",
"observedAt": "2026-10-22T23:16:51.011Z"
}

Input | Output | Pricing

Coverage Output Billing

Table of contents

What you get

Each record can carry these 58 fields. A field the source does not publish for a record comes back as null.

FieldTypeDescription
buildingSignalIdstringStable BuildingSignal building ID (same building across years and runs)
jurisdictionstringCity, county, state or province of the program
programNamestringName of the disclosure or compliance program
countrystringCountry code (US or CA)
reportingYearnumberData year of the report
sourceRecordIdstringBuilding ID used by the program
propertyNamestringProperty or building name
addressStreetstringStreet address
citystringCity
statestringState or province
zipstringZIP or postal code
latitudenumberLatitude
longitudenumberLongitude
parcelIdstringTax parcel / lot identifier (BBL, SSL, APN, folio, etc.)
binstringNYC Building Identification Number (BIN)
propertyTypestringProperty type normalized to ENERGY STAR Portfolio Manager categories
propertyTypeRawstringProperty type exactly as published
grossFloorAreaSqftnumberGross floor area (sq ft)
yearBuiltnumberYear built
numberOfBuildingsnumberNumber of buildings on the property
energyStarScorenumberENERGY STAR score (1-100; 50 = national median, 75+ = top performer)
siteEuiKbtuSqftnumberSite energy use intensity (kBtu per sq ft per year)
weatherNormalizedSiteEuiKbtuSqftnumberWeather-normalized site EUI (kBtu per sq ft)
sourceEuiKbtuSqftnumberSource energy use intensity (kBtu per sq ft)
siteEnergyUseKbtunumberTotal annual site energy use (kBtu)
electricityKwhnumberAnnual grid electricity use (kWh)
naturalGasThermsnumberAnnual natural gas use (therms)
districtSteamKbtunumberAnnual district steam use (kBtu)
fuelOilKbtunumberAnnual fuel oil and diesel use (kBtu)
waterUseKgalnumberAnnual water use (thousand gallons)
ghgEmissionsMtco2enumberTotal greenhouse gas emissions (metric tons CO2e)
ghgIntensityKgco2eSqftnumberGHG emissions intensity (kg CO2e per sq ft)
complianceStatusstringNormalized status: compliant, not_submitted, non_compliant, exempt, pending or other
complianceStatusRawstringCompliance/reporting status exactly as published
sourcestringOfficial source program or agency
boroughstringNYC borough
councilDistrictnumberCity council district
residentialUnitsnumberNumber of residential units
largestUseTypestringLargest property use type
largestUseSqftnumberFloor area of the largest use (sq ft)
secondUseTypestringSecond-largest property use type
secondUseSqftnumberFloor area of the second-largest use (sq ft)
thirdUseTypestringThird-largest property use type
thirdUseSqftnumberFloor area of the third-largest use (sq ft)
electricityKbtunumberElectricity use (kBtu)
naturalGasKbtunumberNatural gas use (kBtu)
fuelOil2KbtunumberNo. 2 fuel oil use (kBtu)
fuelOil4KbtustringNo. 4 fuel oil use (kBtu)
fuelOil56KbtustringNo. 5/6 fuel oil use (kBtu)
fuelOil1KbtustringNo. 1 fuel oil use (kBtu)
dieselKbtunumberDiesel use (kBtu)
propaneKbtustringPropane use (kBtu)
districtSteamKbtuRawnumberDistrict steam use (kBtu)
districtHotWaterKbtustringDistrict hot water use (kBtu)
districtChilledWaterKbtunumberDistrict chilled water use (kBtu)
nationalMedianSiteEuinumberNational median site EUI for this property type
energyStarCertificationYearsstringYears the building earned ENERGY STAR certification
observedAtstringWhen this record was collected (ISO timestamp)

Input and filters

All inputs are optional.

FieldTypeRequiredDefaultDescription
reportingYearsarrayno(none)Only these reporting years, e.g. 2023, 2024. Leave empty for the most recent year of every building.
latestYearOnlybooleannotrueReturn only the most recent report of each building (ignored when reporting years are set). Turn off to get the full history.
propertyTypesarrayno(none)Keep only buildings whose type contains any of these words, e.g. Office, Multifamily, Hotel, Warehouse.
minFloorAreaSqftintegerno(none)Only buildings at least this large.
maxFloorAreaSqftintegerno(none)Only buildings up to this size.
minSiteEuiintegerno(none)Only buildings using at least this much energy per square foot. High EUI = retrofit opportunity.
maxSiteEuiintegerno(none)Only buildings using at most this much energy per square foot.
minEnergyStarScoreintegerno(none)Only buildings with at least this ENERGY STAR score (1-100).
maxEnergyStarScoreintegerno(none)Only buildings with at most this ENERGY STAR score (1-100). Low scores = inefficient buildings.
complianceStatusesarrayno(none)Keep only these reporting/compliance statuses. Values: compliant, not_submitted, non_compliant, exempt, pending.
zipCodesarrayno(none)Only buildings in these ZIP or postal codes.
ownerKeywordstringno(none)Only buildings whose published owner or responsible entity contains this text (where the program publishes it).
maxBuildingsintegerno50Maximum number of buildings to return. Free Apify plans are limited to 10 per run.

A working example to paste into the Input tab:

{
"maxBuildings": 25
}

Use cases

  • Pull fuel-by-fuel use to find NYC buildings still burning oil or steam for an electrification pitch.
  • Compare water use across a multifamily portfolio using waterUseKgal.
  • Join LL84 rows to your own NYC property data through bin.

Coverage and freshness

Program: NYC Local Law 84 Benchmarking. Publisher: NYC LL84 Energy & Water Disclosure. Area in this example record: New York City, NY. Each run reads the current official publication, so a scheduled run picks up new releases when the agency publishes them. Fields the program does not publish come back as null.

Pricing

This actor uses pay-per-event pricing. These are the current Apify prices, read on 2026-11-06.

EventPriceWhen it is charged
result$0.015Each building delivered to your dataset
apify-actor-start$0.003When a run starts, once per GB of run memory with a minimum of one

At the default 512 MB, a run that delivers 100 buildings costs $1.503.

  • Accounts on the free Apify plan receive up to 10 results per run.
  • If nothing matches your filters, no results are charged. If the source cannot be read before any result is saved, you get one row with an error field, and that row carries no result charge. The start event still applies to the run.
  • Set a maximum cost per run and the actor stops delivering results when it reaches that limit.

Comparison with other Apify actors

No dedicated actor for this source on the Apify Store as of November 2026. We searched the public Store on 2026-11-06 with queries including "nyc building energy", "nyc energy benchmarking" and "ll84", and we reviewed the listings for this source and data type. Store listings change, so run the same search before you rely on this.

Other public BuildingSignal actors for the same buyer:

FAQ

What do EUI and ENERGY STAR score mean?

Site EUI is the energy a building uses per square foot per year; higher means less efficient for its type. The ENERGY STAR score (1-100) compares a building to similar buildings nationwide: 50 is the median, 75+ is top performer.

Why are some values empty?

Programs publish different fields, and buildings that did not report have no energy values. Empty values are returned as null rather than guessed.

Where does the data come from?

From official public records and open-data disclosures published by the government programs named on this page. BuildingSignal standardizes them into one consistent schema. Always confirm critical decisions with the issuing agency.

Can I use it with my CRM or BI tool?

Yes. Export to CSV, Excel or JSON, call it through the Apify API, or connect it with the Make, Zapier, n8n or Google Sheets integrations.

Run it through the Apify API

Replace <TOKEN> with your Apify API token.

curl -X POST "https://api.apify.com/v2/acts/buildingsignal~nyc-ll84-energy-water-disclosure/run-sync-get-dataset-items?token=<TOKEN>" \
-H "Content-Type: application/json" \
-d '{"maxBuildings": 25}'

With the Apify CLI:

$apify call buildingsignal/nyc-ll84-energy-water-disclosure --input '{"maxBuildings": 25}'

Every run writes to a dataset that you can export as JSON, CSV or Excel from the Storage tab or through the Apify API.


BuildingSignal is an independent data provider and is not affiliated with, endorsed by or sponsored by any government agency or program named on this page. Data comes from official public records; always confirm critical decisions with the issuing agency.