South Africa's remaining grid connection capacity per substation from the official NTCSA GCCA 2025 data — available MW, binding constraint, committed generation and supply-area limits. Filter by region, status and capacity. From $0.002/connection point, PPE.
Track South Africa's remaining electricity grid connection capacity per substation, straight from the official NTCSA Generation Connection Capacity Assessment (GCCA) 2025. Instead of parsing the raw Excel workbook and working out the binding network constraint yourself, this actor returns one clean record per connection point with the effective available capacity (MW), the binding constraint, committed generation and the four published level limits — plus change detection between runs.
South Africa's grid is one of the most congested in the world: in GCCA 2025 the Northern Cape, Western Cape, Eastern Cape and Hydra Central supply areas are fully depleted (0 MW remaining), and only about 19.94 GW remains across the other six supply areas. The best wind and solar regions have no capacity left, so developers must look elsewhere — this actor shows exactly where.
What it returns
- Effective available capacity (MW) per substation — the lowest of the four GCCA levels (substation, substation area, local area, supply area), which is the actual number a developer cares about.
- Binding constraint — which of the four network levels is limiting the connection point.
- Committed generation (MW) already contracted at the point, split by technology (wind, PV, CSP, dispatchable).
- All four level limits (MW) so you can see the full picture and re-derive anything yourself.
- Connection status —
available(≥ 100 MW),limited(1–99 MW),full(0 MW),unknown. - Transformer capacity, connection voltages and how many source rows were merged.
- Change flags (
isNewSinceLastRun,isChangedSinceLastRun,capacityDeltaMW) driven by a persistent snapshot, so scheduled runs surface only what actually moved. - A free run summary with totals, a per-supply-area breakdown and the top substations by available capacity.
Data source and method
- Source: NTCSA Generation Connection Capacity Assessment (GCCA) 2025 results workbook (official file, GCCA portal).
- The actor resolves the current results workbook link from the GCCA portal on every run (so it survives the
annual filename change) and falls back to the known URL if the portal is unreachable. The resolved URL is
echoed in every record's
sourceUrl. - The GCCA states capacity at four levels and notes that "the stated generation connection capacity is limited by the lowest capacity at all the levels". This actor applies exactly that rule.
- One source substation code can span several transformer-bank rows; the actor merges them (substation-level limit summed over the banks, the three higher levels taken as the maximum) into one record per connection point.
- The actor does not forecast or invent numbers. It only restructures and classifies the official data.
- Data is published annually; the current file is the GCCA 2025 assessment (with a NERSA-approved curtailment update published in November 2025). Change detection therefore typically reports a batch of movements once a year.
Sanity check: the committed generation summed across all connection points is ~19,411 MW (≈ 19.4 GW), which matches the total reported in the GCCA 2025 document.
Input
| Field | Type | Description |
|---|---|---|
supplyAreas | array (select) | Optional filter on one or more of the 10 official supply areas. |
localAreas | array (select) | Optional filter on one or more of the 34 official local areas. |
connectionStatus | array (select) | Optional filter on available, limited, full, unknown. |
minAvailableCapacityMW | number | Only substations with at least this much effective available capacity (MW). |
maxAvailableCapacityMW | number | Only substations with at most this much effective available capacity (MW). |
onlyChangedSinceLastRun | boolean | Default true. Deliver only new/changed substations after the baseline. Set to false for the full filtered snapshot on every run. |
Example inputs
Find large connection opportunities in KwaZulu-Natal and Gauteng:
{ "supplyAreas": ["KwaZulu-Natal", "Gauteng"], "minAvailableCapacityMW": 500, "onlyChangedSinceLastRun": false }
Find every depleted connection point (useful for supply-area risk analysis):
{ "connectionStatus": ["full"], "onlyChangedSinceLastRun": false }
Output
One dataset item per connection point:
{"recordType": "substation","key": "KwaZulu-Natal|ATHEN4","supplyArea": "KwaZulu-Natal","localArea": "Empangeni","substation": "ATHEN4","substationName": "ATHENE","connectionStatus": "available","bindingConstraint": "substation","availableCapacityMW": 1425,"substationLimitMW": 1425,"substationAreaLimitMW": 4000,"localAreaLimitMW": 3810,"supplyAreaLimitMW": 5500,"committedGenerationMW": 0,"committedWindMW": 0,"committedPvMW": 0,"committedCspMW": 0,"committedDispatchableMW": 0,"transformerCount": 4,"installedTransformerMVA": 2000,"connectionVoltages": ["400/132"],"sourceRowCount": 1,"isNewSinceLastRun": false,"isChangedSinceLastRun": false,"previousAvailableCapacityMW": null,"capacityDeltaMW": null,"source": "NTCSA Generation Connection Capacity Assessment (GCCA) 2025","sourceUrl": "https://www.ntcsa.co.za/wp-content/uploads/2024/06/GCCA_2025_Results_Report.xlsx","scrapedAt": "2026-10-01T05:51:19.896Z"}
A single recordType: "summary" item is added at the end of each run with totals, supplyAreas[],
countByConnectionStatus and topSubstationsByAvailableCapacityMW[].
Two capacity totals are reported, and the distinction matters:
totalRemainingGridCapacityMW— the distinct remaining transmission capacity across all supply areas (the sum of each area's publishedSupply_Area_Limit; ≈ 19,940 MW in GCCA 2025). This is the figure to quote.sumOfConnectionPointAvailabilityMW— the sum of per-connection-point availability. Area-level limits are shared between substations, so this deliberately over-counts and is not a portfolio total; use it only as a relative indicator. EachsupplyAreas[]entry carries bothremainingSupplyAreaCapacityMW(distinct) andsumOfConnectionPointAvailabilityMW.
Use cases
- Renewable-energy developers – find the substations with the most remaining headroom before committing to a site.
- Grid connection consultants – screen a region and understand why a point is constrained.
- Battery / data-centre investors – identify substations where new load or storage can still connect.
- Energy analysts – track how GCCA capacity reallocates between the depleted Cape areas and the Free State, North West, Limpopo and Mpumalanga.
- Agentic workflows – expose grid-capacity screening as a tool for an AI assistant via Apify MCP.
Pricing
Pay per event:
| Event | Price | When |
|---|---|---|
substation-record | $0.002 | Per connection-point record delivered (after the free baseline run). |
capacity-change | $0.01 | Extra, per record that is new or changed since the previous run. |
The very first run seeds the persistent baseline and is free (nothing is charged). With the default
onlyChangedSinceLastRun: true, later runs deliver and charge only what changed.
Legal
NTCSA is a public entity and the GCCA data is publicly published. This actor only restructures and aggregates non-personal infrastructure data — no personal data, no GDPR concerns. Users remain responsible for complying with the NTCSA website terms when redistributing the underlying data.
FAQ
Why do so many substations show 0 MW? Because the Northern Cape, Western Cape, Eastern Cape and Hydra Central supply areas are fully allocated in GCCA 2025. Those connection points are real, but not available for new generation.
Is this per address or postcode? No. The GCCA is regional: capacity is published per substation / supply area, not per address. This actor reflects that granularity honestly.
What does bindingConstraint mean?
The four GCCA levels each state a remaining capacity; the connection point is limited by the lowest one. The
actor reports that level (e.g. substation means the substation's own transformation capacity is the bottleneck,
while supply_area means the whole supply area is the bottleneck).
How often is the data updated? The GCCA is an annual publication. Between editions, a scheduled run mostly confirms "no change".
Keywords
South Africa grid capacity, NTCSA GCCA, Eskom grid connection queue, grid congestion South Africa, netcongestie, renewable energy South Africa, wind connection capacity, solar PV grid capacity, battery storage grid connection, supply area capacity, curtailment, wheeling, substation capacity, Gauteng grid capacity, KwaZulu-Natal grid capacity, Limpopo grid capacity, Western Cape depleted.
Related Actors
- UK Grid Capacity Tracker (NESO TEC register) — the UK equivalent, from the official NESO TEC register.
- NL Netcongestie Monitor — the Dutch per-address grid-capacity monitor that started this portfolio.
When should an AI agent use this?
- "Which South African substations still have at least 500 MW of grid connection capacity?"
- "Is there grid capacity available for a wind project in KwaZulu-Natal or Limpopo?"
- "Show me all depleted connection points in the Western Cape supply area."
- "How much committed generation is connected at the Athene substation, and what limits its remaining capacity?"
- "What changed in South African grid connection capacity since the last check?"
- "Compare remaining grid capacity across all ten NTCSA supply areas."
Changelog
- v0.1 — Initial release: NTCSA GCCA 2025 per-connection-point capacity, effective available capacity with binding constraint, technology split, supply-area summary, persistent change detection.