Spot Missing or Bad Ship Fuel Meter Readings (FuelEU Check) avatar

Spot Missing or Bad Ship Fuel Meter Readings (FuelEU Check)

Pricing

$4.50 / fueleu voyage meter & gap pre-audit

Go to Apify Store
Spot Missing or Bad Ship Fuel Meter Readings (FuelEU Check)

Spot Missing or Bad Ship Fuel Meter Readings (FuelEU Check)

Compares ship fuel meter numbers against engine power to spot stuck meters or fuel bypasses, and locks missing-meter notes against later edits.

Pricing

$4.50 / fueleu voyage meter & gap pre-audit

Rating

0.0

(0)

Developer

Recoup-IQ

Recoup-IQ

Maintained by Community

Actor stats

0

Bookmarked

2

Total users

1

Monthly active users

10 days ago

Last modified

Features

Limited permissions

Share

Compare Ship Fuel Meter Readings With Expected Fuel Use (FuelEU Pre-Check)

This tool compares two series that you supply: the fuel flow your meter logged and the fuel flow you expected (for example from engine load). It flags the places where the two series do not agree. It also locks gap notes in a hash chain, so a later edit shows.

The tool cannot see a pipe or a meter. A flag tells you that your two series disagree. A person must find the cause.

What This Tool Checks

  1. Flow against expected flow (riq_fueleu_meter_guard_ex): 16 to 4,096 pairs in 0.1 kg per hr units. The tolerance is tolerance_pct (default 5). Flags:
    • 0x01: The flow value almost never changes, but the expected value moves by more than the tolerance (a frozen meter signal).
    • 0x02: The flow is below the expected value by more than the tolerance, over the whole window or over a run of samples.
    • 0x04: The flow is above the expected value by more than the tolerance, over the whole window or over a run of samples.
    • 0x08: The flow repeats a short loop (3 to 16 samples) exactly, and the expected value does not.
  2. Gap note seal (riq_fueleu_chain_gap_record): Locks gap notes into a BLAKE2b hash chain. A later text edit changes the chain receipt.

Test Results (Synthetic Data Only)

We tested the check on synthetic data, not on data from a ship. Tolerance 5 %, 64 samples, 100 random seeds for each noisy case:

  • Healthy series: 0 flags in 100 runs for each noise level of 1 %, 2 %, 3 % and 5 %, and for a short 16-sample window with 2 % noise.
  • A steady 9,010 against 9,000 pair and a clean ramp: 0 flags.
  • Flow 3 % below expected: not flagged (this is below the tolerance).
  • Flow 5 % below expected: flagged in 44 of 100 runs (this is at the tolerance).
  • Flow 8 %, 12 % or 18 % below expected: flagged in 100 of 100 runs.
  • Frozen meter while the expected value moves: flagged in 100 of 100 runs. A frozen meter at a steady load cannot be seen.
  • An 8-sample replay loop: flagged in 100 of 100 runs.
  • Set the tolerance above the normal noise of your own data. The test is in verification/tangential_demands_bench/fuel_guard_test.c.

How to Run It

  1. Click Start with blank samples to see a free demo on two synthetic series (no charge).
  2. If you have your own data, paste 16 or more pairs into samples. A run with your data costs one event.
  3. If you have gap notes, paste them into gap_records.

Plain Limits to Know First

  • The tool only compares the two series that you supply. The result is only as good as your expected flow values.
  • Tests used synthetic data only. We did not test it on ship data or ship pipes.
  • This tool gives a pre-check only. It does not replace an accredited FuelEU verifier.
  • A trained person must check all flagged trips before you file.

Onboard Ship Software and Contact