Net Zero Air avatar

Net Zero Air

Pricing

from $5.00 / 1,000 air calculations

Go to Apify Store
Net Zero Air

Net Zero Air

Compare indoor and outdoor air. Ventilate when the outside holds less heat and less water.

Pricing

from $5.00 / 1,000 air calculations

Rating

0.0

(0)

Developer

Josh Berry

Josh Berry

Maintained by Community

Actor stats

0

Bookmarked

1

Total users

0

Monthly active users

2 months ago

Last modified

Categories

Features

Limited permissionsSingle-tenantServer interface

Share

What does Net Zero Air do?

Net Zero Air tells you whether outdoor air should come in. Send an indoor reading and an outdoor reading. You get the water the air is holding, the enthalpy it carries, and a call: ventilate, hold, or a named tradeoff.

Try it from the Input tab or POST JSON to /compare. On Apify you get a stable API URL, scheduling, monitoring, and pay-per-calculation billing — you pay when you ask, not while the Actor sits idle.

Why use Net Zero Air?

A thermostat only sees temperature. Two rooms at the same dry-bulb can carry very different amounts of water, and the heat that rides with that water is what a cooling coil actually pays for. Net Zero Air turns the sensors you already have into one decision: open to outdoor air, or keep it to the minimum the space needs for air quality.

  • Ventilate when outdoor air is the cheaper air. The default call opens outdoor air only when it carries less heat and does not hold more water.
  • Name the trade when the two disagree. Cooler air that is wetter is a cooling tradeoff. Drier air that is hotter is a drying tradeoff. Set intent to cooling or drying if you want that trade to count as ventilate.
  • One POST instead of a psychrometric chart. Controllers, dashboards, and scripts send both readings and get a call back. No-code users fill the Input tab and run.
  • Metric or imperial, same field names. units: "metric" is °C, hPa, mL of water per m³, and kJ/kg. units: "imperial" is °F, inHg, US fl oz per 1,000 ft³, grains/lb, and Btu/lb.
  • The same air sample, the other questions. /state is one reading. /comfort is an occupied-zone vote. /adaptive is for a window-ventilated room. /stress is outdoor heat.

How to use Net Zero Air

  1. Open this Actor on Apify.
  2. On the Input tab, set indoor and outdoor dry-bulb and relative humidity, plus station pressure or elevation.
  3. Click Start — or POST the same JSON to /compare on the Standby URL.
  4. Read recommendation. ventilate means bring outdoor air in. hold means keep outdoor air at the minimum needed for air quality.

API example:

curl -X POST "https://sciguy--psychrometrics.apify.actor/compare" \
-H "Authorization: Bearer <APIFY_TOKEN>" \
-H "content-type: application/json" \
-d '{
"units": "metric",
"intent": "both",
"pressure": 1013.25,
"indoor": {"dry_bulb": 24, "relative_humidity": 50},
"outdoor": {"dry_bulb": 18, "relative_humidity": 40}
}'

A classic run writes the same result to the default dataset. Point a thermostat, an energy dashboard, or a morning check at it.

Deltas are outdoor minus indoor. A negative delta_enthalpy means outdoor air carries less heat. A negative delta_water_volume means it holds less water.

Input

/compare needs units and two readings. Each reading needs dry_bulb and either relative_humidity or humidity_ratio. Both readings share pressure (hPa or inHg) or elevation (m or ft). Flat Console fields (indoor_dry_bulb, outdoor_relative_humidity, …) are the same request.

Optional: intent (both default, cooling, drying), pressure_type (absolute default, or sea_level with elevation), enthalpy_margin (default 0.5 kJ/kg), water_margin (default 0).

/state is one reading: dry_bulb, moisture, and pressure or elevation.

/comfort needs dry_bulb, relative_humidity, metabolic_rate (met), and clothing (clo). Mean radiant defaults to dry-bulb. Air speed defaults to 0.1 m/s (ft/min if imperial).

/adaptive needs dry_bulb and prevailing_outdoor (the running mean outdoor temperature). Same radiant and air-speed defaults.

/stress needs dry_bulb and relative_humidity. Wind defaults to 1 m/s at 10 m (mph if imperial). Mean radiant defaults to dry-bulb.

Output

You can download the dataset in JSON, HTML, CSV, or Excel. A typical comparison:

{
"units": "metric",
"intent": "both",
"recommendation": "ventilate",
"reasons": [
"Outdoor air carries less heat.",
"Outdoor air holds less water.",
"Bring outdoor air in."
],
"indoor_water_volume": 10.88,
"outdoor_water_volume": 6.15,
"indoor_enthalpy": 47.76,
"outdoor_enthalpy": 31.02,
"delta_water_volume": -4.73,
"delta_enthalpy": -16.74,
"assumptions": ["unit system metric", "absolute pressure"]
}

water_volume is millilitres of liquid water per cubic metre of air when units is metric, and US fluid ounces per 1,000 cubic feet when imperial. enthalpy is kJ per kg of dry air, or Btu per lb. Each reading also includes wet-bulb, dew point, humidity ratio, vapor pressure, and an si object that stays in SI.

Data table

FieldMeaning
recommendationventilate, hold, cooling_tradeoff, or drying_tradeoff
intentThe rule that produced the call
indoor_water_volume / outdoor_water_volumeWater the air is holding
indoor_enthalpy / outdoor_enthalpyHeat the air is carrying
delta_water_volume / delta_enthalpyOutdoor minus indoor
reasonsThe heat line, the water line, and the action
siThe same reading in SI, on /state and inside each side of /compare

/comfort returns pmv, ppd, and sensation (ISO 7730). /adaptive returns comfort_temperature, the 80% and 90% bands, and whether the room sits inside them (ASHRAE 55). /stress returns heat_index (Rothfusz, from 27 °C upward, otherwise null), humidex on its native scale, and utci with stress_category.

Pricing / Cost estimation

How much does it cost to know when to open? $5.00 USD per 1,000 successful calculations — $0.005 each time /compare, /state, /comfort, /adaptive, /stress, or a Console run returns a result. You are not billed while the API sits idle. A house checking once an hour is about twelve cents a day.

There is no crawl and no long run: each request is a short CPU answer. Set a schedule and only pay when you actually ask.

Tips or Advanced options

  • Compare enthalpy, not dry-bulb alone. Outdoor air can be cooler and still carry more heat when it is holding a lot of water.
  • Send station pressure or elevation. At elevation the same relative humidity is more water per kilogram of dry air.
  • If the weather report is sea-level pressure, set pressure_type to sea_level and include elevation.
  • humidity_ratio is grains per pound in imperial and kg water per kg dry air in metric. Send it when the sensor already reports absolute moisture.
  • The enthalpy margin exists so a 0.1 kJ/kg flicker does not open a damper. Set enthalpy_margin to 0 if you want any decrease to count.
  • /adaptive is the check for a room that is allowed to open its windows. /compare is the check for whether the outdoor air itself is worth bringing in.

FAQ, disclaimers, and support

Net Zero Air estimates water, enthalpy, a comfort vote, and a ventilation call from the readings you send. It is not a controls design and it does not replace the minimum outdoor air a code or an air-quality sensor requires. hold means “do not increase outdoor air for energy or moisture,” not “seal the building.”

Using the Actor to drive dampers or windows is your responsibility.

Questions and feature requests: use the Actor Issues tab. A private deployment or extra indexes are available as a custom solution.