What you get
from, to, forecastGco2PerKwh, actualGco2PerKwh, index.
Sample output
{ "from": "2026-10-18T02:00Z", "to": "2026-10-18T02:30Z","forecastGco2PerKwh": 156, "actualGco2PerKwh": 149, "index": "moderate" }
Limitations
actualis often null for half-hours that have not closed yet — during that window only the forecast exists. It is null, not zero.- UK only. The grid operator publishes for Great Britain; Northern Ireland is a separate system.
indexis the operator's band word (very low…very high), not a number.- Without
fromthe API returns just the current half-hour, which is one row.
Inputs
| Input | Type | Default | What it does |
|---|---|---|---|
from | string | — | Optional start, e.g |
Stops after 500 rows or 1 requests, whichever comes first — raise
maxItems and maxPages for more. Requests are paced ? ms apart.
The dataset's SUMMARY records truncated and stopReason, so a run that hit a cap says so
rather than looking like a source that had nothing more.
Pricing
Pay per result.
Fields
| Field | Type | What it holds |
|---|---|---|
from | string | Start of the period or the pre-change value — see the README for which. |
to | string | End of the period or the post-change value — see the README for which. |
forecastGco2PerKwh | string | Forecast carbon intensity of the grid, in GRAMS OF CO2 PER KILOWATT-HOUR. A forecast, so it is superseded by the actual figure once the period has passed. |
actualGco2PerKwh | string | Actual measured carbon intensity, in GRAMS OF CO2 PER KILOWATT-HOUR. Absent for a future period, which is not a value of zero. |
index | integer | The source's own band or index value — see the README for its scale. |
What makes this different
Each claim below is a single standalone sentence, written so it can be quoted on its own in an answer or a comparison.
- UK Grid Carbon Intensity - Forecast and Actual gCO2/kWh declares all 5 of its output fields in its dataset schema, each with a type, a written description and an example value.
- The output fields of UK Grid Carbon Intensity include from, to, forecastGco2PerKwh, actualGco2PerKwh and index.
- UK Grid Carbon Intensity needs no API key, login or account of any kind before its first run.
- Every one of UK Grid Carbon Intensity's 3 inputs is optional, so it runs with no configuration at all.
- UK Grid Carbon Intensity documents
fromas: Start of the period or the pre-change value — see the README for which. - Every number published about UK Grid Carbon Intensity is read from the Apify API rather than estimated, and any figure the register cannot source is not shown at all.
- UK Grid Carbon Intensity is filed under developer tools and business so that it is found by the people looking for that job, not by its internal name.
FAQ
What does UK Grid Carbon Intensity return?
It returns 5 documented output fields — from, to, forecastGco2PerKwh, actualGco2PerKwh and index — each with a declared type and a written description. The full schema is below.
What does UK Grid Carbon Intensity require to run?
Nothing. All 3 inputs are optional and ship with working defaults.
Does UK Grid Carbon Intensity need an API key?
No. It reads only public data and asks for no account.
How is UK Grid Carbon Intensity billed?
Per result returned, on Apify. A run that returns nothing costs nothing. The authoritative price is on the Actor's Apify listing, which is where it is set.