FDA 510(k) Premarket Clearances Scraper
Pricing
from $12.48 / 1,000 results
FDA 510(k) Premarket Clearances Scraper
Scrape FDA 510(k) premarket clearances from the official openFDA database. Filter by device, applicant, product code, medical specialty, state, country, clearance type and decision date. Enrich with device class and regulation. Export JSON, CSV, Excel.
Pricing
from $12.48 / 1,000 results
Rating
0.0
(0)
Developer
Scrapers Lat
Maintained by CommunityActor stats
0
Bookmarked
2
Total users
1
Monthly active users
10 days ago
Last modified
Categories
Features
Share
FDA 510(k) Premarket Clearances Scraper
The applicantTotalClearances, applicantRecentClearances, applicantRecallCount, applicantRecentRecalls and aiSummary fields are populated only when you enable the optional paid add-ons described in Billing and limits; otherwise they are null.
Here is one real result, with every field the actor returns:
{"kNumber": "K252812","deviceName": "UniPearls® Embolic Microspheres","applicant": "Suzhou Haowei Medical Technology Co., Ltd.","contact": "Jinyan Shi","addressLine1": "Rm. 304, Bldg. 4, Tianyun Sq., 111 Wusongjiang Ave.","addressLine2": "Wuzhong District","city": "Suzhou","state": null,"postalCode": "215124","countryCode": "CN","decisionCode": "SESE","decisionDescription": "Substantially Equivalent","decisionDate": "2026-07-31","dateReceived": "2025-09-04","reviewDays": 330,"productCode": "KRD","advisoryCommittee": "CV","advisoryCommitteeDescription": "Cardiovascular","clearanceType": "Traditional","thirdPartyReview": false,"expeditedReview": false,"statementOrSummary": "Summary","deviceClass": "2","genericDeviceName": "Device, Vascular, For Promoting Embolization","medicalSpecialtyDescription": "Cardiovascular"}
The example above shows the first 25 of 36 fields.
What it does
The actor queries the official FDA 510(k) premarket notification database, applies whichever filters you pass as input, paginates through the matching clearances, and writes one normalized record per clearance to the run's dataset. Dates are normalized to YYYY-MM-DD, missing source values are returned as null, and each record is enriched from the FDA device classification so you get deviceClass, regulationNumber, genericDeviceName and medicalSpecialtyDescription without a second lookup. Two derived fields are added on top: reviewDays (calendar days from submission to decision) and clearanceUrl (a direct link to the official 510(k) database entry).
Coverage is the full US 510(k) clearance database (well over 175,000 records going back decades). This is the premarket clearance dataset, which is distinct from device adverse events, device recalls and device establishment registrations.
Quickstart
Open the actor, paste this into the input, and press Run. It returns the 10 most recent cardiovascular device clearances decided since 2023.
{"advisoryCommittee": "Cardiovascular","decisionFrom": "2023-01-01","maxResults": 10}
Billing and limits
This actor is billed pay per result: you are charged one result event per clearance record written to the dataset, and nothing when a run finds no matches or fails. Free Apify plans are capped at 10 results per run; upgrade for larger pulls. Very large filtered sets are paginated up to the source ceiling, so for bulk exports narrow by date range or another filter and page through.
Two optional add-on events are available, both off by default and disabled for free plans:
applicant_profile($0.012 per clearance): enabled withwithApplicantProfile. Makes extra FDA lookups to build the applicant's regulatory profile (same-company clearance track record plus linked device recalls). Charged only when the profile is built.ai_summary($0.012 per clearance): enabled withwithAiSummary. Uses AI to produce a concise plain-English summary of the clearance for non-expert buyers. Charged only when a usable summary is produced, never on an empty or failed AI response.
Both add-ons respect your maxTotalChargeUsd spend limit.
