Water Heater Size & Cost Calculator (Tank, Tankless) avatar

Water Heater Size & Cost Calculator (Tank, Tankless)

Pricing

Pay per event

Go to Apify Store
Water Heater Size & Cost Calculator (Tank, Tankless)

Water Heater Size & Cost Calculator (Tank, Tankless)

What size water heater a home needs, from plain text: the busiest hour's hot water and the first-hour rating for gas, electric and heat pump tanks, tankless flow and BTU or kW for the fixtures running at once, tank recovery, and the yearly running cost of every kind of heater.

Pricing

Pay per event

Rating

0.0

(0)

Developer

Jumble Mog

Jumble Mog

Maintained by Community

Actor stats

0

Bookmarked

2

Total users

1

Monthly active users

9 hours ago

Last modified

Features

Limited permissions

Share

Size a tank or tankless water heater for a home, check a tank's recovery, or compare what gas, electric, propane and heat pump heaters cost to run, from one line of text. Ask what size water heater for 4 people and 2.5 baths or tankless for 2 showers and the kitchen sink, cold climate and you get back:

  • Tank size by first-hour rating (FHR): the hot water your busiest hour takes (showers, washing up, food prep, laundry, the dishwasher) and which common tanks rate at least that much.
  • Tankless size: the flow of the fixtures running at once, the temperature rise from your cold water to the heater setting, and the gas input (BTU/h) or electric power (kW, amps and breaker) that takes, with the flow each standard unit gives.
  • A tank's recovery: gallons an hour, the hours to heat a full tank and its estimated first-hour rating, from its size and burner or element.
  • Yearly running cost of seven kinds of heater at your prices, with the energy each uses.
  • Charts and a Markdown report with every assumption.

It's made for:

  • Homeowners and buyers choosing a replacement heater.
  • Plumbers, HVAC contractors and home inspectors who want a quick, explained sizing.
  • AI agents, home-improvement apps and quoting tools that need water heater numbers they can show their work for.

A chart made by this Actor for 4 people and 2.5 baths: the busiest hour's hot water (4 showers 48.5 gal, hands and face 16, food prep 5, clothes washer 7) and the first-hour rating of eleven common tanks against the 77 gal needed, with the 50 and 75 gal gas tanks and the 65 and 80 gal heat pump tanks in green

How to use it

  1. Write Requests, one per entry. The form has examples.
  2. Optionally set the fuel, cold water and heater setting temperatures, and your electricity and gas prices.
  3. Click Start. Each request is a row in the results, with its summary, chart and report.

What you can write

You writeIt means
4 people, family of 3, 2.5 bathsThe household (a tank sizing)
gas, electric, propane, heat pumpThe fuel
tankless, on demand, 2 showers and the kitchen sink, 1 bathroom sinkA tankless sizing and the fixtures running at once
with laundry and the dishwasher, 2.5 gpm shower, 10 minute showers, low flowMore in the busiest hour, and the shower
inlet 45 F, 40 F inlet, cold climate, warm climate, 140 F setpoint, 70 F riseTemperatures (°C works too)
50 gallon electric 4500 W recovery, 75 gallon gas tank 75000 btuOne tank's recovery
running cost for 4 people, 80 gal per day, $0.15/kWh, $1.30/therm, propane $2.75/galRunning cost

The same as an object: {"type": "tank", "people": 5, "bathrooms": 3, "fuel": "gas", "showerFlow": 2.5}.

Examples

  • what size water heater for 4 people and 2.5 baths → about 77 gal in the busiest hour: a 50 gal gas tank (FHR about 77) or a 65 gal heat pump tank (FHR about 79).
  • family of 2, 1 bathroom, electric → 38 gal FHR: a 40 gal electric tank.
  • tankless for 2 showers and the kitchen sink, cold climate → 5.5 gpm with a 78 °F rise needs about 226,000 BTU/h: two 199,000 BTU/h units, or fewer fixtures at once.
  • electric tankless for 1 shower and 1 bathroom sink, inlet 60 F → 3 gpm, 26.6 kW (111 A at 240 V): a 27 kW unit.
  • 50 gallon electric 4500 W recovery → 29.1 gallons an hour at a 62 °F rise, about 1.5 hours to heat a full tank, FHR about 55.
  • water heater running cost for 4 people, $0.15/kWh, $1.30/therm → a heat pump about $142 a year, gas tankless $169, gas tank $245, electric tank $571.

How-to examples

These are examples from Examples above, written as complete inputs; the result lines are from their runs.

How to size a water heater for a family

{"requests": ["what size water heater for 4 people and 2.5 baths"]}

Result: About 77 gal in the busiest hour: a 50 gal gas tank (FHR about 77) or a 65 gal heat pump tank (FHR about 79).

How to size a tankless water heater

{"requests": ["tankless for 2 showers and the kitchen sink, cold climate"]}

Result: 5.5 gpm with a 78 °F rise needs about 226,000 BTU/h: two 199,000 BTU/h units, or fewer fixtures at once.

How to compare water heater running costs

{"requests": ["water heater running cost for 4 people, $0.15/kWh, $1.30/therm"]}

Result: A heat pump about $142 a year, gas tankless $169, gas tank $245, electric tank $571.

How to let an AI agent size a water heater

Add this Actor to the Apify MCP server with https://mcp.apify.com/?tools=jumblemog/water-heater-calculator. The agent writes the household ("4 people and 2.5 baths") and passes on the tank or tankless size and running cost instead of guessing them.

FAQ

What can it do? Size a tank by first-hour rating, size gas or electric tankless units by flow and temperature rise, work out a tank's recovery, and compare yearly running costs.

Which fuels does it cover? Gas, electric, heat pump and tankless models of each.

Why does tankless need two units in cold climates? Colder inlet water means a bigger temperature rise, so the same flow needs more BTU than one unit delivers.

How large a building? Homes of 1-20 people and 0.5-10 bathrooms; larger buildings need a commercial sizing.

How many can I run at once? Up to 200 requests per run, each as a line of text or an object. A request that can't be computed isn't billed.

Does it work with Zapier, Make or n8n? Yes. Call the Actor with its Apify app or an HTTP request and pass the results on.

Input

FieldWhat it is
requestsTank sizings, tankless sizings, tank recoveries or running costs, as lines of text or objects (up to 200 per run)
fuelFuel when a request doesn't say
inlet, setpointCold water and heater setting in °F when a request doesn't say
electricPrice, gasPriceYour prices per kWh and per therm
chartsDraw a chart for each request (default on)

Output

One dataset item per request, also saved together in the run's OUTPUT record:

{
"request": 1, "status": "ok", "type": "tank", "title": "Water heater size for 4 people, 2.5 baths",
"summary": "4 people, 2.5 baths: about 77 gal of hot water in the busiest hour, so a first-hour rating of 77 gal or more: 50 gal gas (FHR about 77), 65 gal heat pump (FHR about 79).",
"household": {"people": 4, "bathrooms": 2.5, "showers": 4, "showerFlow": 2.0, "showerMinutes": 8, "inlet": 58, "setpoint": 120},
"sizing": {"peakHourDemand": 76.5, "firstHourRatingNeeded": 77, "recommended": ["50 gal gas", "65 gal heat pump"]},
"demand": [{"use": "shower", "count": 4, "gallonsEach": 12.1, "gallons": 48.5}],
"options": [{"tank": "50 gal gas", "kind": "gas", "gallons": 50, "firstHourRating": 77.0, "meets": true}],
"units": {"volume": "gal", "flow": "gpm", "temperature": "°F", "gas": "BTU/h", "power": "kW", "cost": "USD"}
}

A tankless sizing has tankless, fixtures and models; a recovery has tank; a running cost has use and heaters. Every item has warnings, notes (every assumption and default), a Markdown report and links to the chart and report. A request that can't be computed has "status": "failed" and the reason in error, and isn't billed.

How it works

  1. Busiest hour: each shower takes flow × minutes of mixed 105 °F water (2 gpm, 8 minutes by default), of which the hot share is (105 − cold) ÷ (setting − cold); one shower per person, plus hands and face, food prep and the clothes washer, and the dishwasher or a bath when you say.
  2. First-hour rating: 70% of the tank plus an hour of recovery at a 90 °F rise, the way label values come out; heat pump tanks use typical label values. The tank must rate at least the busiest hour.
  3. Recovery = input × efficiency ÷ (8.34 × rise) gallons an hour (gas 78-80%, electric elements 98%).
  4. Tankless input = gpm × 500 × rise ÷ efficiency BTU/h (95% condensing gas, 82% non-condensing), or gpm × 500 × rise ÷ 3412 ÷ 0.99 kW for electric; the breaker is 125% of the current.
  5. Cold water: 58 °F (the DOE test value) for tanks and costs, 50 °F for tankless unless you give yours or a climate or place (very cold 37, cold or northern 42, mild or central 50, warm or southern 58, Florida or tropical 68 °F).
  6. Running cost = gallons a day × 365 × 8.34 × rise ÷ the uniform energy factor (gas tank 0.64, gas tankless 0.93, electric tank 0.93, electric tankless 0.98, heat pump 3.75), at 16 gal a person a day unless you give it, and $0.17/kWh, $1.45/therm and $2.75 a gallon of propane by default.

Pricing

You pay one low price per request, at the price shown on this page: a tank sizing or recovery, a tankless sizing and a running cost comparison are each one event. The charts and report are included. Requests that can't be computed are never charged. If you set a maximum cost per run, the Actor stops before a request that wouldn't fit.

Speed

A request takes milliseconds. A run through the API answers in about 10 seconds, including the cloud container starting.

Tips and limits

  • Check the label. The first-hour rating is on the yellow EnergyGuide label; compare models by it, not by tank gallons.
  • Tankless in cold climates often needs two units or fewer fixtures at once; electric tankless can need 100-150 A of service.
  • Follow local code and the manufacturer for venting, gas line size and wiring.
  • Limits: homes of 1-20 people and 0.5-10 bathrooms (larger buildings need a commercial sizing); 200 requests per run.

For AI agents and developers

This Actor works with the Apify MCP server, so AI agents can call it as a tool. Pass requests as plain text and read summary, sizing, tankless, heaters and warnings. A direct API call that waits for the answer:

curl -X POST "https://api.apify.com/v2/acts/jumblemog~water-heater-calculator/run-sync-get-dataset-items?token=YOUR_TOKEN" \
-H "Content-Type: application/json" \
-d '{"requests": ["what size water heater for 3 people and 2 baths, gas", "tankless for 2 showers, cold climate"]}'

run-sync instead returns the run's OUTPUT: the status, the counts and every result as JSON.

In Python, with the apify-client package:

from apify_client import ApifyClient
client = ApifyClient("YOUR_TOKEN")
run = client.actor("jumblemog/water-heater-calculator").call(run_input={
"requests": [{"type": "tank", "people": 5, "bathrooms": 3, "fuel": "gas"}],
})
for item in client.dataset(run["defaultDatasetId"]).iterate_items():
print(item["summary"])

Credits

  • Method: the DOE uniform energy factor test (10 CFR 430 Appendix E) and common plumbing sizing practice.
  • Charts: Vega-Lite and vl-convert (BSD-3-Clause), with the Inter font (SIL Open Font License).